VISTA-50P/VISTA-50PUL Programming Form 
Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, 
see the Partition-Specific Fields section for programming these fields. Standard default (*97) values are shown in brackets [  ]. 
 
*00
  INSTALLER CODE  
   |   |   |     
 
 
Enter 4 digits, 0-9   [4140] 
*02   *05 
RESPONSE TYPES FOR ZONES  
 
Skip these fields. Use #93 Menu Mode, Zone 
Programming to program the response types. 
*09
  ENTRY DELAY #1 
 
[02]
   |     
 
 
00, 02-15 times 15 seconds
 
 
Maximum "03" for UL. 
*10
  EXIT DELAY #1 
[03] 
   |     
 
 
00, 03-15 times 15 seconds
 
 
Maximum "04" for UL installations.
 
*11
  ENTRY DELAY #2  
[06]
   |     
 
 
00, 02-15 times 15 seconds (must be longer than Entry Delay 
#1). Maximum "03" for UL installations. 
*12 
EXIT DELAY #2 
[08]
   |     
 
 
00, 03-15 times 15 seconds (must be longer than Exit Delay 
#1). Maximum "04" for UL installations.
 
*13
  ALARM SOUNDER DURATION 
[04]
   |     
 
 
01-15 times 2 minutes.  Must be minimum 16 minutes for UL 
installations.  
*14 
ZONE 9 RESPONSE TIME 
[0] 
     
 
 
Enter 1 for fast response time 10ms 
 
Enter 0 for normal response time 350ms. 
 
Must be 0 for UL installations. 
*15 
KEYSWITCH ASSIGNMENT 
[0] 
     
 
 
Enter partition in which keyswitch used,  
 1-8; 
0=disable 
*16 
CONFIRMATION OF ARMING DING 
[0] 
     
 
 
1=enable; 0=disable.   
 
Must be "1" for UL Installations.  
*17 
AC LOSS KEYPAD SOUNDING 
[0] 
     
 
 1=yes; 
0=no 
*19
  RANDOMIZE AC LOSS REPORT 
[0] 
     
 
 
1=10-40 min; 0=normal report (about 2 min. after AC loss). 
*20
  VIP MODULE PHONE CODE 
   |         |     
 
 
Enter 01 - 09 for the first digit; enter  
[00], 
[11]  
 
11 for “*” or 12 for “#” for the second digit. 
 
Must be set to "0" for UL installations. 
*21
  PREVENT FIRE TIMEOUT 
[0] 
     
 
 
1=No timeout; 0=Timeout. 
*22
  KEYPAD PANIC ENABLES 
[001] 
                 
 
 
1=enable; 0=disable 
 
995 996 999
 
*23 
MULTIPLE ALARMS  
[1] 
     
 
 
1=yes; 0=no   
*24 
IGNORE EXPANSION ZONE TAMPER  
 [0]
       
 
 
1=Ignore; 0=Enable tamper for RF and RPMs.   
 
Must be "0" for UL installations if using these devices. 
*25
  BURG.TRIGGER FOR RESPONSE TYPE 8  [1] 
     
 
 1=enable; 
0=disable 
*26
  INTELLIGENT TEST REPORTING 
[0] 
     
 
  
1=yes (no report sent if any other report was recently sent); 
0=no (send report at programmed interval, field *27) 
Must be 0 for UL installations. 
*27 
TEST REPORT INTERVAL   
[024
]     |   |   |     
 
 
Enter interval in hours, 001-999; 0000=no report;  
 
Max. 024 for UL installations. 
*28
  POWER UP IN PREVIOUS STATE 
[1] 
     
 
 
1=yes; 0=no;  "1" for UL installations. 
*29 
QUICK ARM    
[1] 
     
 
 1=yes; 
0=no 
 
*30
  TOUCHTONE OR ROTARY DIAL 
[0] 
     
 
 
1=TouchTone; 0=rotary 
*31
  PABX ACCESS CODE 
  |       |       |       |    
 
 
00-09; B-F (11-15) 
*32 
PRIM. SUBS. ACCT #  
  |       |       |       |    
 
 
Enter 00-09; B-F (11-15)  [15  15  15  15] 
*33
  PRIMARY PHONE NUMBER 
 
                                                           
 
 
                                         
 
 
Enter 0-9 for each digit.  Enter #11 for *, #12 for #,  
 
#13 for 2 second pause
 
*34
  SECONDARY PHONE NUMBER 
 
 
                                                           
 
 
                                         
 
 
Enter 0-9 for each digit.  Enter #11 for *, #12 for #,  
 
#13 for 2 second pause 
*35 
DOWNLOAD PHONE NO. 
 
                                                           
 
 
                                         
 
 
Enter 0-9 for each digit.  Enter #11 for *, #12 for #,  
 
#13 for 2 second pause 
*36 
DOWNLOAD ID NO. 
 
   |         |         |         |         |         |         |         |      
 
 
Enter 00-09; A-F (10-15)  [15 15 15 15 15 15 15 15] 
*37 
DOWNLOAD COMMAND ENABLES 
   
Dlr Shtdwn
   
Sys Shtdwn
 0 
Not Used
   
Rmt Byp
   
Rmt Disarm
   
Rmt Arm
   
Upld Pgm
   
Dwnld Pgm
 
 
See field 1*53 for Callback disable option; [1=enable]; 
0=disable. For UL installations, all entries must be "0." 
*38
  PREVENT ZONE XX BYPASS 
[00] 
   |     
 
 
01-86; 00 if all zones (except fire zones) can be bypassed