Frame Relay configuration task list
185
SmartWare Software Configuration Guide 
15 • Frame Relay configuration
node(pvc)[1]#shutdown
Check the PVC 1 status by using 
show running-config
 and verify that the entry shutdown occurs in the con-
figuration part responsible for this PVC.
node(pvc)[1]#show running-config
Running configuration:
#----------------------------------------------------------------#
#                                                                #
# 2500                                                           #

pvc 1
  encapsulation rfc1490
  bind interface wan router
  shutdown
  exit
Debugging Frame Relay
A set of commands is available to check the status of the Framerelay connections, fragmentation process and 
keepalive message exchange. Be aware that some monitors generate a lot of output and can seriously impact 
your system performance.This procedure describes how to display the Frame Relay configuration settings for 
the serial interface
Mode: Administrator execution
Command
Purpose
[no] debug framerelay
Prints the status of the different monitors (ON or 
OFF)
[no] debug framerelay all
Enables/Disables all framerelay debug monitors
[no] debug framerelay error
Enables/Disables monitor which prints only 
occurred errors.
[no] debug framerelay lmi
Enables/Disables monitor which prints keepalive 
events and messages
[no] debug framerelay management
Enables/Disables monitor which prints management 
and configuration events
[no] debug framerelay packets
Enables/Disables monitor which prints dlci, size and 
fragmentation status of every incoming and outgo-
ing packet. Be aware that this monitor can seriously 
impact your system performance.