Introduction
214
SmartWare Software Configuration Guide 
18 • ISDN Overview
The S reference point is on the subscriber interface. This is the typical 4-wire connection between an ISDN 
phone and an ISDN PBX. Be aware that many ISDN PBX vendors use non-standard proprietary 2-wire inter-
faces to connect the Terminals to the PBX.
The T reference point is on the trunk interface of a PBX. This is the standard 4-wire interface between the PBX 
and the network termination unit (NTU) also known as NT1 in standard terminology. The ISDN layer 2 pro-
tocol at this point is in point-to-point mode between the NTU and the PBX.
The 4-wire layer 1 specification S and T interfaces is foreseen for in-house installations and carries a maximum 
of 150 meters.
The S/T reference point is on a point-to-multipoint S-Bus. Here several terminals are connected directly to the 
same BRI NTU. The S and T reference points are “collapsed”. The NT2 is not represented by any equipment 
unit.
The U reference point is on the transmission side of the NTU designed to carry the ISDN line over the last 
mile. For basic rate interfaces this is typically a DSL technology working on legacy copper pairs over a distance 
up to 12 kilometers. For primary rate lines, DSL, coax and fiber transmission is in use. In most European 
countries the U interface is not accessible to the subscriber, the operator always provides the NT1. In the US 
and some other countries the NT1 can be integrated into the NT2, i.e. the PBX is connected directly to the U 
interface.
The V reference point is typically a y-wire interface between the line card of the public switch and the 2 Mbps 
transmission equipment which transports the PRI signal over copper (DSL), coax or fiber.
Possible SmartNode port configurations
The SmartNode ISDN ports can be configured for connection to S, T, S/T, and V interfaces. Refer to 
ISDN UNI Signaling
ISDN is a User-Network Interface (UNI) signaling protocol with a user and a network side. The user side is 
implemented in ISDN terminals (phones, terminal adapters, etc.) while the network side is implemented in 
the exchange switches of the network operator. Both sides have different signaling states and messages. Smart-
Ware ISDN ports can be configured to work as user (USR) or network (NET) interfaces. 
A SmartNode in some applications does not replace a standard ISDN equipment (PBX or Terminal) but is 
inserted between an existing NT and PBX. In such cases the SmartNode ISDN ports are configured to operate 
the opposite side of the connected equipment as illustrated in 
Figure 32. ISDN signaling side
S
U
T
PBX
Legend:
USR
User Side Signaling
NET
Network Side Signaling
TE
Phone
NT2
NT1
T
Node
USR
NET
NET
USR
IP Network