Patton electronic SmartNode 4110 Series ユーザーズマニュアル

ページ / 664
FXO interface configuration task list
422
SmartWare Software Configuration Guide 
36 • FXO interface configuration
Configuring how to detect a call has disconnected (optional)
When a call has disconnected, the FXO interface may detect and verify the termination of the phone call by 
three different methods.
Detect a busy tone or release tone
Detect a loop break (if provided by the FXS switch)
Detect battery reversal (if provided by the FXS switch)
Detect a dtmf signal
Configure loop break timing
The selection of the method, if any of the three, is via the 
disconnect-signal
 command. The default enables 
only loop-break. Upon detecting a loop break, the FXO interface proceeds to clear the call on the SmartNode. 
In some instances, the user may need to transmit all of the in-band information (tone signal, announcement) 
to the end party after disconnection has occurred.
The 
disconnect-signal
 command can be used to enable or disable the three detection methods. If all three 
methods are disabled, the call is cleared after a period of 30 seconds from reception of the disconnect signal. 
Consequently it becomes the responsibility of the end party to execute the on-hook (completing the discon-
nection phase) for the call to be completely cleared.
Note
Verify that the busy and release tones are correctly configured for the country 
where the SmartNode is installed (see chapter 42, 
page 529 for configuration information. If the tones are improperly config-
ured, the FXO port will not detect them, resulting in missed phone calls.
Mode: Interface FXO
Step
Prompt, command & response
Purpose
1
node(if-fxo)[if-name]#[no] disconnect-signal 
{battery-reversal | busy-tone | loop-break}
The default is Loop-break. To disable it, use 
the no inverse command. Should all three 
methods be disabled, the call is cleared 30 
seconds after receiving the disconnect signal.
The default setting of loop-break is not dis-
played in the running-config output.
2
[name] (if-fxo) [interface]# [no] disconnect-sig-
nal dtmf <dtmf-digits>
Disconnects the call upon reception of one of 
the specified DTMF digits.
3
[name] (if-fxo) [interface]#loop-break-duration 
[min <min-time>] [max <max-time>]
Specifies the timing of the loop break signal. 
Shorter breaks are ignored, longer breaks 
are treated as line down.
Min specifies the minimum time of a valid 
loop break (Default 60ms). Max specifies the 
maximum time of a valid loop break (Default 
600ms). Please note that the internal timer 
has a resolution of 40ms.