Mitsubishi Electronics QD75MH1 ユーザーズマニュアル

ページ / 838
 
 
 
9 - 69 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
 Current feed value during 1-axis speed control 
The following table shows the "
Md.20
Current feed value" during 1-axis speed 
control corresponding to the "
Pr.21
Current feed value during speed control" 
settings. 
 
Pr.21
Current feed value during speed 
control" setting 
Md.20
Current feed value 
0: Do not update current feed value 
The current feed value at speed control start 
is maintained. 
1: Update current feed value 
The current feed value is updated. 
2: Zero clear current feed value 
The current feed value is fixed at 0. 
 
V
t
In speed control
Current feed value during speed control start is maintained
(a) Current feed value not updated
t
Current feed value is updated
(b) Current feed value updated
(c) Current feed value zero cleared
t
0
In speed control
In speed control
V
V
 
 
 Restrictions 
(1)  Set "Positioning complete" in "
Da.1
Operation pattern". An axis error 
"Continuous path control not possible (error code: 516)" will occur and the 
operation cannot start if "continuous positioning control" or "continuous path 
control" is set in "
Da.1
Operation pattern".  
("Continuous positioning control" and "continuous path control" cannot be set 
in speed control.) 
(2)  Set the WITH mode in "
Pr.18
M code ON signal output timing" when using 
an M code.  The M code will not be output, and the M code ON signal will not 
turn ON if the AFTER mode is set. 
(3)  An error "No command speed (error code: 503)" will occur if the current speed  
(-1) is set in "
Da.8
command speed". 
(4)  The software stroke limit check will not carried out if the control unit is set to 
"degree".