AT&T 585-310-231 ユーザーズマニュアル

ページ / 180
Issue  2.0   December 1995
5-1
 
5
MERLIN LEGEND Switch 
Administration
This chapter describes how to administer the MERLIN LEGEND system for 
integration with the Intuity system. Be sure to have the MERLIN LEGEND system 
forms that you completed in Chapter 2.
Disconnect Signaling Reliability
Use this procedure to classify the disconnect signal sent by the central office on 
loop-start trunks as reliable. The selected setting applies to all trunks in the 
system; trunks cannot be programmed individually. The disconnect signaling 
reliability does not apply to ground-start trunks emulated on a T1 facility.
To set the disconnect signaling reliability:
1. From the System Programming menu, select Lines and Trunks.
On the console: Select 
LinesTrunks
.
On the PC: Press 
.
The Lines and Trunks menu appears.
2. Select Touch-Tone/Loop Start  Disconnect.
On the console: Select 
TT/LS Disc
.
On the PC: Press 
.
The TouchTone/LS Disconnect menu appears.
3. Select Loop Start Disconnect.
On the console: Select 
LS Disconnect
.
On the PC: Press 
.
The LS Reliable Disconnect menu appears.
F4
F3
F2