Galil DMC-13X8 ユーザーズマニュアル

ページ / 210
Chapter 2  Getting Started  
  30  
USER MANUAL 
 
TE X  (CR) 
Tell error 
a few times, and get varying responses, especially with reversing polarity, it indicates system vibration.  
When this happens, simply reduce KD. 
Next you need to increase the value of KP gradually (maximum allowed is 1023). You can monitor the 
improvement in the response with the Tell Error instruction 
 
KP 10 (CR) 
Proportion gain 
 
TE X (CR) 
Tell error 
As the proportional gain is increased, the error decreases. 
Again, the system may vibrate if the gain is too high.  In this case, reduce KP.  Typically, KP should 
not be greater than KD/4.  (Only when the amplifier is configured in the current mode). 
Finally, to select KI, start with zero value and increase it gradually.  The integrator eliminates the 
position error, resulting in improved accuracy. Therefore, the response to the instruction 
 
TE X  (CR) 
becomes zero.  As KI is increased, its effect is amplified and it may lead to vibrations.  If this occurs, 
simply reduce KI.  Repeat tuning for the Y, Z and W axes.  
For a more detailed description of the operation of the PID filter and/or servo system theory, see 
Chapter 10 - Theory of Operation.
 
Design Examples 
Here are a few examples for tuning and using your controller.  These examples have remarks next to 
each command - these remarks must not be included in the actual program. 
Example 1 - System Set-up 
This example assigns the system filter parameters, error limits and enables the automatic error shut-off. 
Instruction Interpretation 
KP10,10,10,10 
Set gains for a,b,c,d (or X,Y,Z,W axes) 
KP*=10 
Alternate method for setting gain on all axes 
KPX=10 
Alternate method for setting X (or A) axis gain 
KPA=10 
Alternate method for setting A (or X) axis gain 
KP, 20 
Set Y axis gain only 
 
 
Instruction Interpretation 
OE 1,1,1,1 
Enable automatic Off on Error function for all axes 
ER*=1000 
Set error limit for all axes to 1000 counts 
KP10,10,10,10 
Set gains for a,b,c and d axes 
KP*=10 
Alternate method for setting gain on all axes 
KPX=10 
Alternate method for setting X (or A) axis gain 
KPA=10 
Alternate method for setting A (or X) axis gain 
KP,,10 
Set Z axis gain only 
KPZ=10 