2-8 Wiring of the peripheral control
2 - 35
2-8 Wiring of the peripheral control
2-8-1 Wiring of the Input/output circuit
The input/output circuit to control the external signal such as external emergency stop input and relay 
changeover signal output is wired.
The input/output circuit for each unit is as follows.
For a switch or relay to be wired, use a switch or relay that satisfies the input/output (voltage, current)
conditions.
Input condition
Output condition
Switch ON
18VDC to 25.2VDC
5mA or more
Output voltage
24VDC ±5%
Tolerable output
current Io
40mA or less
Switch OFF
4VDC or less
1mA or less
Interface name
Selection example
For digital input signal
Use a minute signal switch which is stably contacted and operated even with low 
voltage or current
<Example> OMRON: G2A, G6B type, MY type, LY type
For digital output signal 
Use a compact relay operated with rating of 24VDC, 50mA or less.
<Example> OMROM: G6B type, MY type
15 
CN9
CN9
24V 
DICOM
 
20 
EMGX
 
5.6k  
19 
DI 
5.6k  
13 
DOCOM
 
MBR
 
MC
 
24V 
 
 
(1)
 
(2)
DICOM
 
20 
EMGX
 
5.6k  
19 
DI 
5.6k  
 
CN9
connector
connector
Input circuit
Output circuit
Relay, etc.
Relay, etc.
When DICOM is connected to 24V
Select the polarity of DICOM
When DICOM is connected to 24G
connector
External emergency
stop
Proximity switch
(Note) For DICOM,
(1) the common input signal pattern (24V or 24G) is used.
(2) whichever polarity of the input can be used, however, the direction must be the same.