Mitsubishi Electronics IB-1500193(ENG)-D ユーザーズマニュアル

ページ / 528
MDS-D-SVJ3/SPJ3 Series Instruction Manual
2-6 Connection of power supply
2 - 31
2-6 Connection of power supply
2-6-1 Power supply input connection
Drive the contactor via the relay from the contactor control output of the (MC) CN9 connector.
1. Make sure that the power supply voltage is within the specified range of each unit. Failure to 
observe this could lead to damage or faults.
2. For safety purposes, always install a circuit protector, and make sure that the circuit is cut off when 
an error occurs or during inspections.
3. The wire size will differ according to each drive unit capacity.
4. For safety purposes, always install a magnetic contactor (contactor) on the main circuit power 
supply input. Large rush currents will flow when the power is turned ON.
CAUTION
 
 
 
L11 
L21 
L1 
L2 
L3 
MDS-D-SVJ3
 
L11 
L21 
L1 
L2 
L3 
MDS-D-SPJ3
 
MC
15 
DICOM 
 
 

-  

-  
CN9
 
CN9
 
DOCOM
MC
15 
DICOM
DOCOM
There are also types that are
built into the contactor.
Contactor
Class 3
grounding
or higher
3-phase
200 to 230VAC
Contactor
Circuit
protector
Circuit
protector
24VDC
24VDC