ユーザーズマニュアル目次1.0 Introduction51.1 Equipment Inspection51.2 Outside Enclosure Overview6Figure 1 Small enclosure—external features6Figure 2 Large enclosure—internal features61.3 Typical Sequence7Figure 3 Example of typical sequence: Analog input reaches high setpoint71.4 Controller Board Overview8Table 1 Controller board components81.5 LED Indicators10Table 2 LED indicators summary102.0 Installation112.1 Installation Considerations112.1.1 Unpacking and Preliminary Inspection11Packing Contents11Table 3 Packing manifest112.2 Surface-Mounting the Liquitect Panel12Required tools122.2.1 Mounting the Panel12Figure 4 Mounting dimensions122.3 Flush-Mounting the Liquitect Panel13Required tools132.3.1 Mounting the Panel132.4 Connect Power to the Liquitect Panel142.4.1 Input Power Connections - Small Enclosure14Figure 5 Electrical connections to panel142.4.2 Input and Output Power Connections - Large Enclosure15Input Power Connections1524 VAC Output Power Connections15Figure 6 Power wiring to TM11515Figure 7 Power wiring to TM23015Troubleshooting - Transformer Module153.0 Connections and Configuration16Table 4 Wiring specifications163.1 Connecting Leak Detection Cable Inputs173.1.1 Attaching Leak Detection Connection Cable to the Panel173.1.2 Connecting Leak Detection Cable to the Connection Cable18Figure 8 Fittings on leak detection cable (LT500Y) and connection cable (CONNECT10)18Figure 9 Typical leak detection cable layout18Figure 10 Installation of hold- down clips in pairs19Figure 11 Cable laid in straight patterns19Figure 12 Cable laid in circular patterns19Figure 13 90 turn in cable193.2 Connecting Alarm Outputs203.3 Connecting to a Building Maintenance System or External Alarm System203.4 RS422 SiteScan Web Connector213.5 Disable the Audible Horn214.0 Overview of Menus224.1 View Status Overview224.2 System and Control Overview22Figure 14 Menu overview225.0 View Status Options23Figure 15 Menu overview - View Status menu235.1 View Cable Status245.1.1 Cable Status Screens24Viewing Additional Screens24Overall Condition24Table 5 Overall cable conditions24Cable Length & Current Value245.2 View Alarm History255.2.1 Alarm History Log25Table 6 Alarm History Log conditions25Viewing Additional Screens255.3 View Zone Trend265.3.1 Zone Trend Log26Viewing Additional Screens266.0 System and Control Options27Table 7 Valid characters for data entry276.1 Login27Figure 16 Menu overview - System and Control menu286.2 Setup System - Overview296.3 Setup System - Setup ZN1 Zone 129Table 8 Default settings - Zone 1296.3.1 Identify the Zone as Connected306.3.2 Change Zone Label306.3.3 Change Units Label306.3.4 Auto Calibration316.3.5 Set Up Sensitivity for Water Detection316.3.6 Set Up Sensitivity for Contamination Detection326.4 Setup System - Setup ZN2 Zone 2336.5 Setup System - Setup Alarm Outputs34Table 9 Default settings - alarm outputs346.5.1 Specify Longest Cable Length35Table 10 Operation of 420mA outputs356.5.2 Define Relays as Normally Open or Normally Closed356.5.3 Define Alarms as Latched or Unlatched35Liquitect System’s Response to Alarms - Both Latched and Unlatched36Latched Alarms Only36Unlatched Alarms Only366.6 Setup System - Setup Re-Alarm Delay366.7 Setup System - Setup Mapmode37Table 11 Default mapping values376.7.1 View Last Map386.8 Setup System - Setup System Info396.8.1 Change Password39Change the Password39Reset Password to the Factory Default (“AAAA”)396.8.2 Change Date & Time/Automatic Daylight Saving Time406.8.3 Factory Defaults40Table 12 Factory default settings406.9 Reset Latched Alarms416.10 Clear Alarm History426.11 Clear Zone Trend437.0 Specifications447.1 Liquitect Panel Specifications44サイズ: 2.2MBページ数: 48Language: Englishマニュアルを開く