ユーザーズマニュアル目次FrontCover1Safety Precautions3Manual number7Table of Contents9Standards16Certification of UL, cUL standards16Compliance with EC directive (CE Marking)16Requirement for Compliance with EMC directive16Requirement for Compliance with LVD directive17Caution for compliance with EC Directive181. Introduction191.1 Introduction of Manuals191.1.1 Classification of major components in this manual191.1.2 Manual organization and position of this manual201.1.3 List of manuals211.2 Generic Names and Abbreviations Used in Manuals242. Features and Part Names252.1 Major Features252.2 Names and Functions of Parts272.2.1 Front Panel272.2.2 Sides293. Introduction of Products303.1 List of Products and Interpretation of Model Names303.1.1 Main units313.1.2 Expansion boards323.1.3 Connector conversion adapter323.1.4 Special adapters323.1.5 Display module323.1.6 Memory cassette323.2 Connector Types and Cables for Program Communication333.2.1 Programming tool343.2.2 Communication cables343.2.3 Converters and interface344. Specifications, External Dimensions and Terminal Layout (Main Units)354.1 Generic Specifications354.1.1 Dielectric withstand voltage test and insulation resistance test364.2 Power Supply Specifications364.2.1 AC power type364.2.2 DC power type364.3 Input Specifications374.3.1 24 V DC Input (sink/source)374.4 Output Specifications384.4.1 Relay output specifications384.4.2 Transistor output specifications394.5 Performance Specifications404.6 External Dimensions (Weight/Accessories/Installation)424.6.1 Main units424.7 Terminal Layout434.7.1 Interpretation of terminal block layout434.7.2 FX3S-10M*444.7.3 FX3S-14M*444.7.4 FX3S-20M*454.7.5 FX3S-30M*455. Version Information and Peripheral Equipment Connectability465.1 Version Information465.1.1 Manufacturer's serial number check method465.1.2 Version check method475.1.3 Version upgrade history475.2 Programming Tool Applicability475.2.1 Applicable versions of programming tool475.2.2 In the case of programming tool (version) not applicable475.2.3 Program transfer speed and programming tools485.2.4 Cautions on connecting peripheral equipment by way of expansion board or special adapter485.2.5 Cautions on write during RUN495.3 Use of (Built-in USB) Programming Port515.3.1 Installation of USB driver515.3.2 Setting in GX Works2515.4 Cautions on using FA transparent function in GOT1000 Series525.5 Cautions on using transparent port (2-port) function of GOT-F900 Series535.6 Other Peripheral Equipment Applicability545.6.1 Other peripheral equipment applicability546. Examination of System Configuration556.1 Configuration of a Whole System556.1.1 Expansion board/connector conversion adapter/memory cassette system configuration556.1.2 Special adapter system configuration567. Installation In Enclosure577.1 Installation location597.1.1 Installation location in enclosure597.1.2 Space in enclosure597.2 Examination for Installing Method in Enclosure607.3 Procedures for Installing on and Detaching from DIN Rail607.3.1 Preparation for installation607.3.2 Installation of main unit617.3.3 Removal of main unit627.4 Procedures for Installing Directly (with M4 screws)637.4.1 Hole pitches for direct mounting637.4.2 Example of mounting hole pitches647.4.3 Installation of main unit647.5 Connecting Methods for Main Unit and Extension Devices647.5.1 Connection of extension devices647.5.2 Connecting method A - connection of expansion board657.5.3 Connecting method B - connection of connector conversion adapter667.5.4 Connecting method C - connection of special adapter677.6 Application of labels687.6.1 Application of Station No. label (FX3G-485-BD)687.6.2 Application of Station No. label (FX3G-485-BD-RJ)687.6.3 Application of trimmer layout Label (FX3G-8AV-BD)698. Preparation for Wiring and Power Supply Wiring Procedures708.1 Preparation for Wiring728.1.1 Wiring procedures728.2 Cable Connecting Procedures738.2.1 Terminal block [Main unit]738.2.2 Terminal block (for European) [expansion board and special adapters]748.2.3 Grounding terminal of the FX3G-485-BD-RJ758.2.4 Grounding terminal of the FX3U-ENET-ADP768.3 Grounding778.4 Examples of External Wiring [AC power type]788.5 Examples of External Wiring [DC power type]799. Input Wiring Procedures809.1 Before Starting Input Wiring829.1.1 Sink and source input829.2 24 V DC input (Sink and source input type)839.2.1 Handling of 24 V DC input839.2.2 Instructions for connecting input devices849.2.3 Examples of external wiring [AC power type]869.2.4 Examples of external wiring [DC power type]879.3 Input Interruption (I00* to I50*)889.3.1 Allocation of pointers to input numbers (input signal ON/OFF duration)889.3.2 Cautions for input interruption889.3.3 Examples of external wiring899.4 Pulse Catch (M8170 to M8175)909.4.1 Allocation of special memories to input numbers (ON duration of input signals)909.4.2 Cautions for pulse catch909.4.3 Examples of external wiring9110. Use of High-speed Counters9210.1 Outline9210.2 Types of Counting and Operations9210.2.1 Types and input signal forms9210.2.2 High-speed counter device notations9210.2.3 Cautions in connecting mating device9210.3 List of Device Numbers and Functions9310.4 Allocation of Device Numbers to Input Numbers9410.4.1 Allocation table9410.4.2 Restriction of redundant use of input numbers9410.5 Handling of High-speed Counters9510.5.1 1-phase 1-count input9510.5.2 1-phase 2-count input9610.5.3 2-phase 2-count input9710.6 Timing of Updating of Current Value and Comparison of Current Value9810.6.1 Timing of updating of current value9810.6.2 Comparison of current value9810.7 Response Frequency and Overall Frequency9910.8 Examples of External Wiring (Rotary Encoder)10010.8.1 1-phase 1-input [C235 to C245]10010.8.2 2-phase 2-input [C251 to C255]10110.9 Related Devices and Function Switching Procedures10210.9.1 Related devices10210.9.2 [Function switching] switching of allocation and functions of input terminals10310.10 Cautions on Use10311. Use of Built-in Analog10411.1 Outline10511.2 Built-in variable analog potentiometer function10511.2.1 Outline of functions10511.2.2 Applicable PLC10511.2.3 Special data register10511.2.4 Use example of variable analog potentiometer10611.3 Built-in analog input function10711.3.1 Outline of functions10711.3.2 Applicable PLC10711.3.3 Analog input performance specifications10711.3.4 Analog input terminal block10811.3.5 Terminal layout10911.3.6 Analog input line10911.3.7 Special data register10911.3.8 Program example11111.3.9 Changing of input characteristics11111.3.10 Troubleshooting when using built-in analog input11212. Output Wiring Procedures11412.1 External Wiring for Relay Output Type11612.1.1 Product life of relay contacts11612.1.2 Handling of relay output11612.1.3 External wiring precautions11712.1.4 Example of external wiring11812.2 External Wiring of Transistor Output (Sink/Source) Type11912.2.1 Transistor Output Sink and Source11912.2.2 Handling of transistor output11912.2.3 External wiring precautions12112.2.4 Example of external wiring12213. Examples of Wiring for Various Uses12413.1 Notes about Examples of Wiring12513.2 Digital Switch [DSW Instruction (FNC 72)/BIN Instruction (FNC 19)]12613.2.1 When DSW instruction (FNC 72) is used12613.2.2 When BIN instruction (FNC 19) is used12713.3 Input Matrix [MTR Instruction (FNC 52)]12813.4 Seven Segment with Latch [SEGL Instruction (FNC 74)/BCD Instruction (FNC 18)]12913.4.1 When SEGL instruction (FNC 74) is used12913.4.2 When BCD instruction (FNC 18) is used13014. Test Operation, Adjustment, Maintenance and Troubleshooting13114.1 Preparation for Test Operation13214.1.1 Preliminary inspection [power OFF]13214.1.2 Connection to peripheral device connecting connector (RS-422)13214.1.3 Connection to peripheral device connecting connector (USB)13314.1.4 Writing of program and program check [power ON and PLC stopped]13314.2 Running and Stopping Procedures [Power ON]13414.2.1 Methods of running and stopping13414.2.2 Use of several running/stopping methods13514.3 Operation and Test [Power ON and PLC Running]13614.3.1 Self-diagnostic function13614.3.2 Test functions13614.3.3 Program modification function13614.4 Maintenance and Periodic Inspection13714.4.1 Periodic inspection13714.4.2 Maintenance - product life of relay contacts13714.5 Troubleshooting with LEDs13814.5.1 POW LED [on/flashing/off]13814.5.2 ERR LED [on/flashing/off]13814.6 Judgment by Error Codes and Representation of Error Codes13914.6.1 Operation and check by GX Works213914.6.2 Representation of errors14014.6.3 Error Code List and Action14114.7 Troubleshooting14614.7.1 Output does not operate14614.7.2 24 V DC input does not operate14614.7.3 Cautions in registering keyword14715. Other Extension Devices and Optional Units (External Dimensions and Terminal Arrangement)14815.1 Special Adapters14815.1.1 FX3U-4AD-ADP14815.1.2 FX3U-4DA-ADP14815.1.3 FX3U-3A-ADP14915.1.4 FX3U-4AD-PT(W)-ADP14915.1.5 FX3U-4AD-PNK-ADP14915.1.6 FX3U-4AD-TC-ADP15015.1.7 FX3U-232ADP(-MB)15015.1.8 FX3U-485ADP(-MB)15115.1.9 FX3U-ENET-ADP15115.2 Expansion Board15215.2.1 FX3G-4EX-BD15215.2.2 FX3G-2EYT-BD15215.2.3 FX3G-232-BD15315.2.4 FX3G-422-BD15315.2.5 FX3G-485-BD15415.2.6 FX3G-485-BD-RJ15415.2.7 FX3G-2AD-BD15515.2.8 FX3G-1DA-BD15515.2.9 FX3G-8AV-BD15615.3 Connector Conversion Adapter15715.3.1 FX3S-CNV-ADP15715.4 Interface Module15715.4.1 FX-232AWC-H15716. Display Module (FX3S-5DM)15816.1 Specifications15816.1.1 Applicable PLC15816.1.2 Display Specifications15816.1.3 External Dimensions and Part Names15916.2 Installation and Removal15916.2.1 Installation and Removal (when the expansion board/connector conversion adapter is not used together)15916.2.2 Installation and Removal (when the expansion board/connector conversion adapter is used together)16016.3 Summary of Functions16116.4 Flowing of the Screen Display16216.5 Monitor/Test16316.5.1 Relevant devices16316.5.2 Selecting a device16316.5.3 When "Input (X)", "Output (Y)", "Auxiliary relay (M)" or "State (S)" is selected16416.5.4 When "Timer (T)" is selected16616.5.5 When "Counter (C)" is selected16816.5.6 When "Data register (D)" is selected17016.6 Time Display and Setting17216.7 Error Display17216.8 5DM Control Functions (Restrictions From PLC)17316.8.1 System information list17316.8.2 System information setting program example17416.9 Specified Device Monitor Function17416.9.1 System information - specified device monitor function17416.9.2 Program example117516.9.3 Program example2 (when monitoring consecutive timers using operation button)17616.9.4 Program example3 (when monitoring non-consecutive timers using operation buttons)17716.9.5 Specified device editing function17816.10 Back light off function18016.10.1 System Information - Back light off function18016.11 Display Screen Protect Function18116.11.1 System information - display screen protect function18116.11.2 Program example (screen protect function setting)18116.12 Error display enable/disable18116.13 Operation Button ON/OFF Information18216.13.1 Various applications18216.13.2 System information - operation button ON/OFF information18216.14 Specifying a Decimal/Hexadecimal Current Value Display Format18217. Memory Cassette18317.1 Outline18317.2 Specifications18317.2.1 Electrical specifications18317.2.2 Part names and external dimensions18317.3 Installation18417.3.1 Installation (when the expansion board/connector conversion adapter is not used together)18417.3.2 Installation (when the expansion board/connector conversion adapter is used together)18517.4 Removal18717.4.1 Removal (when the expansion board/connector conversion adapter are not used together)18717.4.2 Removal (when the expansion board/connector conversion adapter are used together)18817.5 Saved Data Content18917.6 PROTECT Switch19017.6.1 PROTECT switch setting19017.6.2 PROTECT switch operation19017.6.3 Precautions when setting and using the switch19017.7 Memory Cassette <-> PLC (EEPROM Memory) Transfers by Loader Function19117.7.1 Writing (WR: FX3G-EEPROM-32L -> PLC)19117.7.2 Reading (RD: FX3G-EEPROM-32L <- PLC)19217.8 Memory cassette precautions for use192Appendix A: Special Device List193Appendix A-1 Special Auxiliary Relay (M8000 to M8511)193Appendix A-2 Special Data Register (D8000 to D8511)199Appendix A-3 Analog expansion boards [M8260 to M8269 and D8260 to D8269]204Appendix A-3-1 Special auxiliary relays (M8260 to M8269)204Appendix A-3-2 Special data registers (D8260 to D8269)204Appendix A-4 Analog special adapters [M8280 to M8289 and D8280 to D8289]205Appendix A-4-1 Special auxiliary relays (M8280 to M8289)205Appendix A-4-2 Special data registers (D8280 to D8289)206Appendix B: Instruction List207Appendix B-1 Basic Instructions207Appendix B-2 Step Ladder Instructions207Appendix B-3 Applied Instructions ... in Ascending Order of FNC Number208Appendix C: Discontinued models211Warranty213Revised History214BackCover216サイズ: 5.29MBページ数: 216Language: Englishマニュアルを開く