ユーザーズマニュアル目次1. INTRODUCTION211.1. T703 CALIBRATOR OVERVIEW211.2. USING THIS MANUAL212. SPECIFICATIONS AND APPROVALS232.1. SPECIFICATIONS232.2. CE MARK COMPLIANCE243. GETTING STARTED253.1. UNPACKING AND INITIAL SETUP253.1.1. MODEL T703 CALIBRATOR273.2. ELECTRICAL CONNECTIONS333.2.1. POWER CONNECTION333.2.2. ANALOG OUTPUT TEST CHANNEL CONNECTIONS333.2.3. CONNECTING THE STATUS OUTPUTS343.2.4. CONNECTING THE CONTROL INPUTS353.2.5. CONNECTING THE CONTROL OUTPUTS373.2.6. COMMUNICATION CONNECTIONS383.2.6.1. Ethernet Connection383.2.6.2. USB Option Connection383.2.6.3. RS-232 and RS485 Connection383.2.6.4. Multidrop Network Connection383.3. PNENUMATIC CONNECTIONS393.3.1. DRY AIR IN393.3.2. ZERO AIR IN393.3.3. OUTPUT MANIFOLD403.3.4. EXHAUST403.3.5. MEASURING AN EXTERNAL OZONE SOURCE403.4. INITIAL OPERATION413.4.1. START-UP413.4.2. WARM UP423.4.3. WARNING MESSAGES423.4.4. FUNCTIONAL CHECK443.4.5. OPERATING MODES FOR THE O3 GENERATOR453.4.5.1. CNST (CONSTANT)453.4.5.2. REF (REFERENCE)453.4.5.3. BNCH (BENCH)453.4.6. SETTING THE O3 GENERATOR MODE453.4.7. SETTING THE T703’S OUTPUT FLOW RATE464. FREQUENTLY ASKED QUESTIONS AND GLOSSARY474.1. FAQ’S474.2. GLOSSARY475. OPTIONAL HARDWARE AND SOFTWARE515.1. CARRYING STRAP HANDLE (OPT 29)515.2. COMMUNICATION OPTIONS515.2.1. SERIAL COMMUNICATIONS CABLES (OPT 60A, 60B, 60C, AND 60D)515.2.2. ETHERNET CONNECTION525.2.3. USB OPTION CONNECTION525.2.4. RS-232 MULTIDROP (OPT 62)525.3. NIST TRACEABLE, PRIMARY STANDARD CERTIFICATION526. OPERATING THE T703 CALIBRATOR556.1. TEST FUNCTIONS566.2. OVERVIEW OF OPERATING MODES576.3. STANDBY MODE586.4. GENERAL INFORMATION ABOUT THE GENERATE MODE596.4.1. GENERATE ( AUTO: BASIC GENERATION OF CALIBRATION GAS596.5. AUTOMATIC CALIBRATION SEQUENCES606.5.1. SETUP ( SEQ: PROGRAMMING CALIBRATION SEQUENCES606.5.1.1. Activating a Sequence from the T703 Front Panel616.5.1.2. Naming a Sequence626.5.1.3. Setting the Repeat Count for a Sequence636.5.1.4. Using the T703’s Internal Clock to Trigger Sequences646.5.1.5. Setting Up Control Inputs for a Sequence676.5.1.6. Setting Up Control Outputs for a Sequence686.5.1.7. Setting the Progress Reporting Mode for the Sequences696.5.2. ADDING SEQUENCE STEPS706.5.2.1. The GENERATE Step716.5.2.2. The STANDBY Step726.5.2.3. The DURATION Step726.5.2.4. The EXECSEQ Step736.5.2.5. The CC OUTPUT Step746.5.2.6. Deleting or Editing an Individual Step in a Sequence756.5.3. DELETING A SEQUENCE766.6. SETUP ( CFG776.7. SETUP ( CLK786.7.1. SETTING THE INTERNAL CLOCK’S TIME AND DAY786.7.2. ADJUSTING THE INTERNAL CLOCK’S SPEED796.8. SETUP ( PASS806.9. SETUP ( DIAG ( TEST CHAN OUTPUT: USING THE TEST CHANNEL ANALOG OUTPUT826.9.1. CONFIGURING THE TEST CHANNEL ANALOG OUTPUT826.9.1.1. The Analog I/O Configuration Submenu826.9.1.2. Selecting a TEST Channel Function to Output846.9.1.3. TEST Channel Voltage Range Configuration866.9.1.4. Turning the TEST Channel Over-Range Feature ON/OFF876.9.1.5. Adding a Recorder Offset to the TEST Channel886.9.2. TEST CHANNEL CALIBRATION896.9.2.1. Enabling or Disabling the TEST CHANNEL Auto-Cal Feature906.9.2.2. Automatic TEST Channel Calibration906.9.2.3. Manual Calibration of the TEST Channel Configured for Voltage Ranges936.9.3. AIN CALIBRATION956.10. SETUP ( MORE ( VARS: INTERNAL VARIABLES (VARS)966.11. OPERATING THE T703 CALIBRATOR AS AN O3 PHOTOMETER986.11.1. SET UP FOR OPERATING THE T703 AS AN O3 PHOTOMETER986.12. SETUP ( LVL: SETTING UP AND USING LEADS (DASIBI) OPERATING LEVELS1006.12.1. GENERAL INFORMATION ABOUT LEADS LEVELS1006.12.2. DOT COMMANDS1006.12.3. LEVELS1016.12.4. ACTIVATING AN EXISTING LEVEL1016.12.5. PROGRAMMING NEW LEVELS1026.12.5.1. Creating a Generate LEVEL1036.12.5.2. Editing or Deleting a LEVEL1046.12.6. CONFIGURING LEVEL STATUS BLOCKS1057. OPERATING THE T703 OVER THE SERIAL I/O PORTS1067.1. USING THE ANALYSER’S COMMUNICATION PORTS1067.1.1. RS-232 DTE AND DCE COMMUNICATION1067.1.2. SERIAL COM PORT DEFAULT SETTINGS AND CONNECTOR PIN ASSIGNMENTS1077.1.3. COM PORT BAUD RATE1097.1.4. COM PORT COMMUNICATION MODES1107.1.5. COM PORT TESTING1127.1.6. MACHINE ID1137.1.7. TERMINAL OPERATING MODES1147.1.7.1. Help Commands in Terminal Mode1147.1.7.2. Command Syntax1157.1.7.3. Data Types1157.1.7.4. Status Reporting1167.1.7.5. COM Port Password Security1177.2. REMOTE ACCESS BY MODEM1187.3. MULTIDROP RS-232 SET UP1207.4. RS-485 CONFIGURATION OF COM21227.5. REMOTE ACCESS VIA THE ETHERNET1227.5.1. CONFIGURING THE ETHERNET INTERFACE USING DHCP1237.5.1.1. Manually Configuring the Network IP Addresses1257.5.2. CHANGING THE CALIBRATOR’S HOSTNAME1277.6. APICOM REMOTE CONTROL PROGRAM1288. T703 CALIBRATION AND VERIFICATION1318.1. VERIFYING AND CALIBRATING THE T703’S O3 PHOTOMETER1318.1.1. SETUP FOR VERIFYING AND CALIBRATING THE O3 PHOTOMETER1318.1.1.1. Calibration Manifold Exhaust/Vent Line1328.1.2. VERIFYING O3 PHOTOMETER PERFORMANCE1338.1.3. CALIBRATING THE O3 PHOTOMETER1348.1.3.1. Photometer Zero Calibration1348.1.3.2. Photometer Span Calibration1358.1.4. O3 PHOTOMETER DARK CALIBRATION1368.1.5. O3 PHOTOMETER BACKPRESSURE CALIBRATION1378.2. CALIBRATING THE O3 GENERATOR1388.2.1. O3 GENERATOR CALIBRATION TABLE1388.2.2. VIEWING O3 GENERATOR CALIBRATION POINTS1398.2.3. ADDING OR EDITING O3 GENERATOR CALIBRATION POINTS1408.2.4. DELETING O3 GENERATOR CALIBRATION POINTS1418.2.5. TURNING O3 GENERATOR CALIBRATION POINTS ON / OFF1428.2.6. PERFORMING AN AUTOMATIC CALIBRATION OF THE O3 GENERATOR1438.3. T703 GAS PRESSURE SENSOR CALIBRATION1448.3.1.1. Gas Pressure Sensor Calibration Set Up1448.3.2. CALIBRATING THE REGULATOR AND PHOTOMETER PRESSURE SENSORS1468.4. T703 GAS FLOW CALIBRATION1478.4.1. CALIBRATING THE PHOTOMETER’S SAMPLE GAS FLOW1488.4.2. CALIBRATING THE OUTPUT GAS FLOW1498.4.2.1. Output Gas Flow Set Up1498.4.2.2. Performing an Output Gas Flow Calibration1509. THEORY OF OPERATION1539.1. PNEUMATIC OPERATION1539.1.1. GAS FLOW CONTROL1539.1.1.1. Flow Control Assemblies1539.1.1.2. Photometer Critical Flow Orifice1539.1.2. INTERNAL GAS PRESSURE SENSORS1549.2. ELECTRONIC OPERATION1559.2.1. OVERVIEW1559.2.2. CENTRAL PROCESSING UNIT (CPU)1569.2.2.1. Disk On Module (DOM)1579.2.2.2. Flash Chip1579.2.3. RELAY PCA1579.2.3.1. Valve Control1589.2.3.2. Heater Control1599.2.3.3. Relay PCA Status LEDs and Watch Dog Circuitry1599.2.3.4. Relay PCA Watchdog Indicator (D1)1609.2.4. MOTHERBOARD1619.2.4.1. A to D Conversion1619.2.4.2. Sensor Inputs1619.2.4.3. Thermistor Interface1619.2.4.4. Analog Outputs1619.2.4.5. External Digital I/O1629.2.4.6. I2C Data Bus1629.2.4.7. Power-up Circuit1629.2.5. POWER SUPPLY AND CIRCUIT BREAKER1629.2.6. AC POWER CONFIGURATION1639.2.6.1. AC configuration – Internal Pump (JP7)1649.3. FRONT PANEL TOUCHSCREEN/DISPLAY INTERFACE1659.3.1.1. Front Panel Interface PCA1669.4. SOFTWARE OPERATION1669.5. O3 GENERATOR OPERATION1679.5.1. PRINCIPLE OF PHOTOLYTIC O3 GENERATION1679.5.2. GENERATOR PNEUMATIC OPERATION1689.5.3. O3 GENERATOR ELECTRONIC OPERATION1689.5.3.1. O3 Generator Temperature Control1709.6. PHOTOMETER OPERATION1719.6.1. MEASUREMENT METHOD1719.6.1.1. Calculating O3 Concentration1719.6.1.2. The Measurement / Reference Cycle1729.6.1.3. The Absorption Path1749.6.1.4. Interferent Rejection1759.6.2. PHOTOMETER LAYOUT1769.6.3. PHOTOMETER PNEUMATIC OPERATION1769.6.4. PHOTOMETER ELECTRONIC OPERATION1779.6.4.1. O3 Photometer Temperature Control1779.6.4.2. Pneumatic Sensors for the O3 Photometer17810. MAINTENANCE SCHEDULE & PROCEDURES17910.1. MAINTENANCE SCHEDULE17910.2. PERFORMING LEAK CHECKS18310.2.1. PRESSURE LEAK CHECK18310.3. CLEANING OR REPLACING THE ABSORPTION TUBE18610.4. REBUILDING THE DRY AIR PUMP18610.5. PHOTOMETER UV SOURCE LAMP ADJUSTMENT18710.6. PHOTOMETER UV SOURCE LAMP REPLACEMENT18810.7. ADJUSTMENT OR REPLACEMENT OF OZONE GENERATOR UV LAMP18911. GENERAL TROUBLESHOOTING & REPAIR19111.1. GENERAL TROUBLESHOOTING19111.1.1. FAULT DIAGNOSIS WITH WARNING MESSAGES19211.1.2. FAULT DIAGNOSIS WITH TEST FUNCTIONS19511.1.3. USING THE DIAGNOSTIC SIGNAL I/O FUNCTION19711.2. USING THE ANALOG OUTPUT TEST CHANNEL19811.3. USING THE INTERNAL ELECTRONIC STATUS LEDS19911.3.1. CPU STATUS INDICATOR19911.3.2. RELAY PCA STATUS LEDS19911.3.2.1. I2C Bus Watchdog Status LEDs19911.3.2.2. O3 Status LEDs20011.4. SUBSYSTEM CHECKOUT20111.4.1. VERIFY SUBSYSTEM CALIBRATION20111.4.2. AC MAIN POWER20111.4.3. DC POWER SUPPLY20211.4.4. I2C BUS20311.4.5. TOUCHSCREEN INTERFACE20311.4.6. LCD DISPLAY MODULE20311.4.7. RELAY PCA20411.4.8. PHOTOMETER O3 GENERATOR PRESSURE /FLOW SENSOR ASSEMBLY20411.4.9. MOTHERBOARD20611.4.9.1. A/D Functions20611.4.9.2. Test Channel / Analog Outputs Voltage20611.4.9.3. Status Outputs20711.4.9.4. Control Inputs20811.4.9.5. Control Outputs20911.4.10. CPU20911.4.11. RS-232 COMMUNICATIONS21011.4.11.1. General RS-232 Troubleshooting21011.4.11.2. Troubleshooting Calibrator/Modem or Terminal Operation21011.4.12. TEMPERATURE PROBLEMS21111.4.12.1. Box / Chassis Temperature21111.4.12.2. Photometer Sample Chamber Temperature21111.4.12.3. UV Lamp Temperature21111.4.12.4. Ozone Generator Temperature21211.5. TROUBLESHOOTING THE O3 PHOTOMETER21211.5.1. DYNAMIC PROBLEMS WITH THE O3 PHOTOMETER21211.5.1.1. Noisy or Unstable O3 Readings at Zero21211.5.1.2. Noisy, Unstable, or Non-Linear Span O3 Readings21311.5.1.3. Slow Response to Changes in Concentration21311.5.1.4. The Analog Output Signal Level Does Not Agree With Front Panel Readings21311.5.1.5. Cannot Zero21311.5.1.6. Cannot Span21311.5.2. CHECKING MEASURE / REFERENCE VALVE21411.6. TROUBLESHOOTING THE O3 GENERATOR21511.6.1. CHECKING THE UV LAMP POWER SUPPLY21511.7. TROUBLE SHOOTING THE OPTIONAL O3 GENERATOR21611.7.1. CHECKING THE UV SOURCE LAMP POWER SUPPLY21611.8. REPAIR PROCEDURES21711.8.1. REPAIRING SAMPLE FLOW CONTROL ASSEMBLY21711.8.2. DISK-ON-MODULE REPLACEMENT PROCEDURE21811.9. TECHNICAL ASSISTANCE21812. A PRIMER ON ELECTRO-STATIC DISCHARGE21912.1. HOW STATIC CHARGES ARE CREATED21912.2. HOW ELECTRO-STATIC CHARGES CAUSE DAMAGE22012.3. COMMON MYTHS ABOUT ESD DAMAGE22112.4. BASIC PRINCIPLES OF STATIC CONTROL22112.4.1. GENERAL RULES22112.4.2. BASIC ANTI-ESD PROCEDURES FOR ANALYZER REPAIR AND MAINTENANCE22312.4.2.1. Working at the Instrument Rack22312.4.2.2. Working at an Anti-ESD Work Bench.22312.4.2.3. Transferring Components from Rack to Bench and Back22412.4.2.4. Opening Shipments from Teledyne API Customer Service.22412.4.2.5. Packing Components for Return to Teledyne API Customer Service.225サイズ: 7.38MBページ数: 287Language: Englishマニュアルを開く