Peerless Industries PP730-S 사용자 설명서

다운로드
페이지 20
4 of 20
ISSUED: 10-01-07  SHEET #: 095-9272-2   06-15-09
Installation to Solid Concrete and Cinder Block
Level and use wall plate as template to mark center 
of holes. Drill two 5/16" (8 mm) dia. holes to a
minimum depth of 2.5" (64 mm). Insert anchors (
F) in 
holes flush with wall. Place wall arm assembly (
AA
over anchor and secure with wood screws (
D). Make 
sure wall arm is level, and tighten all fasteners.
D
AA
F
1
solid 
concrete
cinder 
block
1
3
2
F
Drill holes and insert anchors (
F).
Place plate (
AA) over anchors (F) and secure with screws (D).
Tighten all fasteners.
AA
F
D
concrete 
surface
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
•  Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly 
to load-bearing concrete.
•  Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other 
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not 
pull away from concrete when tightening screws. 
If plaster/drywall is thicker than 5/8" (16 mm),
custom fasteners must be supplied by installer (not 
evaluated by UL).
WARNING
CUT
AW
AY
 VIEW
INCORRECT
CORRECT
wall 
plate
wall 
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete