4 of 6
ISSUED: 06-04-10  SHEET #: 120-9084-1
Installation to Double Wood Stud Wall
Wall plate (
A) can be mounted to four studs that are 16" apart. Use a stud finder to locate the edges of the studs. 
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each 
stud’s center. Place wall plate on wall as a template. Level plate, and mark the center of the four mounting holes. 
Make sure that the mounting holes are on the stud center lines. Drill four 5/32" (4 mm) dia. holes 2.5" (65 mm) 
deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (
F) as shown in figure 2.2.
•  Installer must verify that the supporting surface will safely support the combined load of the equipment and all 
attached hardware and components.
•  Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the 
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder 
is highly recommended.
•  Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations. 
WARNING
fig. 2.1
fig. 2.2
A
STUD
F
A
2