ISSUED: 05-29-08  SHEET #: 202-9281-7   12-14-09
Installation to Solid Concrete or Cinder Block
Make sure that wall plate (A) is level, use it as 
a template to mark two mounting holes. The top 
mounting slots should be located 7" (177 mm) above 
the desired screen center as shown in figure 1.1 
on page 4. Drill four 5/16" (8 mm) dia. holes to a 
minimum depth of 2.5" (64 mm). Insert anchors (D) in 
holes flush with wall as shown (right). Place wall plate 
over anchors and secure with two wood screws (C). 
Level, then tighten all fasteners.
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete 
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid 
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to 
avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-
tached hardware and components.
WARNING
•  Tighten screws so that wall plate is firmly attached, 
but do not overtighten. Overtightening can damage 
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete anchors directly to load-
bearing concrete.
•  Never attach concrete anchors to concrete covered 
with plaster, drywall, or other finishing material. 
If mounting to concrete surfaces covered with a 
finishing surface is unavoidable (not evaluated by 
UL), the finishing surface must be counterbored 
as shown below. Be sure concrete anchors do not 
pull away from concrete when tightening screws. If 
plaster/drywall is thicker than 5/8", custom fasteners 
must be supplied by installer (not evaluated by UL).
WARNING
C
A
D
SOLID CONCRETE
CINDER BLOCK
1
CUT
A
W
A
Y
 VIEW
INCORRECT
CORRECT
wall 
plate
wall 
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
A
K
D
C
concrete 
surface