6901-300182 <01>
1
16”, 20”, or 24
1/2”
Studs must be at least 2x4 / 25ga, and the wall must be capable of supporting up to five times the weight of the monitor 
and mount combined. If back side of wall is unfinished, drywall must be installed to a minimum of one stud left and 
right of the stud(s) being used to install the mount.  Drywall must be a minimum of 1/2” thick on each side of the studs, 
and a minimum clearance of 1 7/8 (48mm) behind the wall is required. This product must be centered on the studs. 
If you have any doubts about the ability of the wall to support the total weight of the monitor and mount, contact Sanus 
Systems Customer Service, or a qualified contractor.
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members.
[362 S 125 18, C-Shape, S - Stud Section]
Drywall must be secured to studs with screws 12" on center.
CAUTION