Fabric Watch User’s Guide
3-11
Using Fabric Watch
3
Threshold Area Values
Threshold area values include boundaries and alarms, and apply to all the thresholds within an area. 
Changes are stored in the configuration file.
Boundaries
The following boundary information can be modified:
Unit string
Represents unit value. Only the default unit strings are supported by 
Fabric Watch.
Time base
Time period within which a specified event is measured. Can be 
from one second to one day. Shorter time periods are more sensitive 
to fluctuations and therefore will provide more detailed 
information.
Note:
The Time base boundary can only be modified through a 
telnet command. The Time base bounder does not apply to 
the:
- Transmit performance area
- Receive performance area
- Filter class 
Low boundary
Minimum value. An event is generated if the element value falls 
below this boundary.
High boundary
Maximum value. An event is generated if the element value rises 
above this boundary.
Buffer size
Size of buffer set up to decrease generation of in-between events 
due to oscillation of the element value over a boundary.
Alarms
The following alarms can be added or deleted:
ERRLOG
Logs errors to switch. If configured properly, sends message to 
syslog on daemon.
SNMP-TRAP
Sends trap to SNMP agent.
PORT-LOG-LOCK
Freezes port log to preserve log information generated at time of 
event, for diagnostic purposes.
RAN
Sends alarm messages to remote agent.
Note:
   The RAN alert is only available if the optional Fabric Access 
license has been purchased and turned on.
Email Alert
Sends alarm messages to the corresponding mail address.