MC55 AT Command Set  
3.2 AT+CIND
s
m
obile
MC55_ATC_V01.05
Page 68 of 469
2/10/04
Confidential / Released
 
"unknown") occurs in the list of active calls or when a traffic channel is
established, if 
 setting 
="verbose". 
Also refe
“roam“
Roaming indicator (0-1)
0: Registered to home network or not registered
1: Registered to other network 
“smsfull“
A short message memory storage in the MT has become full (1) or memory
locations are available (0), i.e. range is (0-1) 
“rssi“
Received signal (field) strength (0..5) or (99) if not measurable.
0: signal strength <= -112 dbm
1-4: signal strength in 15 dbm steps
5: signal strength >= -51 dbm
Received signal (field) strength can also be obtained with 
. However,
the signal strength is scaled to value range 0..31 by this command. 
0
Indicator is deregistered. The indicator will not be presented as "
" URC,
but can be queried with 
[1]
(P)
Indicator is registered, indicator event report allowed. 
Notes
• Due to its restrictive range of values, there are events when it is not entirely clear from the context, which
event has led to the output of indicator "call". Rather than as an information in itself, indicator "call" should
therefore be used as a trigger to look up the new call status in the list of current calls with AT commands
• If 
 settin
="verbose", indicator "call" will be issued also when a traffic channel is estab-
lished, or when a call enters states "terminating" or "dropped" (see chapter 
).
In these cases, the relevant information about the cause of the display is available only from AT command
• The indicator "sounder" signals every event a tone is generated in the ME. For instance, if a waiting call pro-
duces a tone, this will be indicated. 
• If the ME is switched on all indicators are in registered state. 
• Use 
 command to allow Indicator Event Report of all registered indicators. 
Example
<state>
(num)
^SYSSTART
AT+CPIN=9999
OK
AT+CIND?
+CIND: 5,99,1,0,0,0,0,0,5
The battery is either full or no battery is connected to the ME. The bit
error rate of the signal quality is not available (since there is no call in
progress). The ME is registered to its home network.
OK
AT+CMER=2,0,0,2
Now activate the Indicator Event Report with 
OK