595-5291-07
TEST AND ADJUSTMENT
NOTE: Sensor has a 30 second warm up period before 
it  will  detect  motion. When  switching  modes  wait  30 
seconds.
1.  Slide  the  sensor  switch  to  the TEST  (center)  posi-
tion.
2.  Place the RANGE adjustment in the medium position 
(halfway between MIN and MAX position).
 
Least Sensitive 
Most Sensitive
Sensor
Motion
60 ft. 
(18.3 m)
8 ft. 
(2.4 m)
 
Maximum Range 
Maximum
 
Coverage Angle
110°
RANGE
OFF
MIN
MAX
TEST
AUTO
Bottom of Sensor
Aim Sensor Down for 
Short Coverage
Aim Sensor Higher for 
Long Coverage
Ball Joint
Clamp Screw
Adjustment of Coverage Area
The sensor detects “motion” by the movement of heat 
(body heat) across the coverage area. However, following 
are examples of objects that also produce heat and can 
cause the sensor to false trigger:
•  Pools of Water 
•  Air Conditioners
•  Dryer Vents 
•  Fenced-In Animals
•  Heating Vents 
•  Automobile Traffic
If you suspect that a heat source of this type is falsely 
triggering the sensor, try reducing the RANGE or aiming 
the sensor away from the heat source in question.
Note: The  detector  is  less  sensitive  to  motion  directly 
towards it and more sensitive to across motion. 
Motion
OPERATION
Place the sensor switch in AUTO for normal operation. If the 
light is not needed, put the switch in the OFF position.
Mode:
On-Time
Works:
Day
Night
Test
5 Seconds
x
x
Auto
30 Seconds
x
THINGS TO REMEMBER
•  Periodically clean the solar panel with a soft cloth and 
warm water. Do not hose spray. Keep the collector clear 
of snow and leaves. Make sure trees and other objects 
do not block sunlight from the panel.
•  If not to be used for several weeks, turn the unit OFF. 
Store it with the panel connected and where the panel 
can gather sunlight.
•  Solar collection is only effective in direct sunlight. Every 
hour the light is on requires a minimum of 16 hours of 
sunlight charging. Solar panels collect less than 10% 
of the sun’s energy. Light bulbs convert this energy to 
light at 5% efficiency.
•  Several days of use with overcast skies may discharge 
the battery. Because of the battery protection circuit, the 
light will not work until the battery is fully recharged.
•  This light is supplied with a 15 Watt, bi-pin, halogen 
bulb. For replacement, use Heath
®
/Zenith model SL-
7000-A1-A or equivalent. Note: Using a larger bulb will 
decrease battery life.
3.  Loosen the clamp screw in the sensor ball joint.
4.  Walk through the coverage area noting when the lights 
turn on. Gently move the sensor head up, down, or 
sideways to change the coverage area. Note: Wait 5 
to 10 seconds after light turns off to retest.
5.  Increase RANGE only as needed. A  larger  RANGE 
setting may cause false triggering and reduce battery 
life.
6.  Secure the sensor into position by tightening the clamp 
screw. Do not overtighten the screw.
7.  After dark, adjust the light to cover desired area.