Heath Zenith SL-7001 사용자 설명서

다운로드
페이지 12
3
595-5291-07
SPECIFICATIONS
Range ........................... Up to 60 ft. (18.3 m); [varies with 
surrounding temperature]
Sensing Angle .............. Up to 110°
Lamp ............................. 15 watt, 6 volt halogen
Battery Type .................. Sealed lead acid, 6 V 6.0 A-Hr.
On Time ........................ 30 seconds, re-triggerable
Full Charge on Time ..... Up to 1 hour
BATTERY REPLACEMENT
This solar light contains a rechargeable battery that can 
be replaced if needed. To replace the battery follow the 
steps below.
Battery Cover Catch Release
Battery 
Cover
Positive Wire
Rechargeable 
Battery
Negative Wire
Tab Slots
DESA  Specialty  Products™  reserves  the  right  to  dis-
continue products and to change specifications at any 
time without incurring any obligation to incorporate new 
features in products previously sold.
IMPORTANT: Replace lamp only with same type lamp, 
20 watts or less. DO NOT reverse the battery wires. 
Damage to the unit will result. Like any lead-acid 
battery, this battery must be disposed of properly.
IMPORTANT:  Keep  sensor  switch  in  the  “OFF” 
position for three days to allow the battery to fully 
charge before testing.
1.  Remove  rear  battery  cover.  Press  in  the  two  catch 
releases on the cover and remove the cover.
2.  Remove rechargeable battery. Slide battery out of case 
and remove the wire connectors from the battery.
3.  Replace battery. Connect the RED wire connector to 
the positive (+) terminal and the BLACK wire connector 
to the negative (-) terminal.
4.  Replace battery cover. Insert the two tabs on the cover 
into the slots on the back of the case. Press the cover 
against the case until the two catch releases snap into 
place.
IMPORTANT: The sealed lead-acid battery must be 