Vermont Casting 1610CE 사용자 설명서

다운로드
페이지 28
13
Defiant 1610CE Non-Catalytic Woodburning Stove
30003846
Install the Optional Ash Door Heat Shield
Many installations will require the use of the supplied 
ash door heat shield. Refer to the “Floor Protection” 
sections starting on Page 9 to determine if your installa-
tion requires the use of the ash door heat shield.
1.  Remove the two Phillips pan head screws from the 
ash door.
2.  Insert the screws through the ash door heat shield 
(from the painted side), place the 8 mm (5/16”) 
spacers over the screws, and carefully thread them 
back into the original holes. (Fig. 21) The curved lip 
should be upward, under the ashlip of the stove.
3.  Tighten securely.
ST539
Attach
ash door
heat shield
11/00
ST538
Spacers
Fig. 21  Install the ashdoor heat shield.
Adjust the Leg Levellers 
Lift the stove slightly so there is no weight on the leg 
while making the adjustment.
Reverse the Flue Collar (If necessary)
Reverse the flue collar by removing the two screws that 
attach it to the back of the stove. Be sure the gasket 
around the flue collar opening is in position when you 
screw the collar back onto the stove.
Attach the Damper Handle 
Use the 1/4” -20 x 3” screw to attach the damper handle 
to the damper stub on the left side. 
Attach the Primary Air Thermostat Handle 
The primary air thermostat handle is the smaller of the 
two black handles. Secure the handle to the stub on 
the right side of the stove with an  8-32 x 2” slot head 
machine screw. (Fig. 22)   
Assemble the Removable Insert Handle
The ceramic removable insert handle opens and closes 
the front doors. Remove after each use, and store it in 
the handle holder behind the right front leg.  Assemble 
the handle by passing the 86 mm (3³⁄₈") screw through 
the ceramic shaft and into the bright metal nub. (Fig. 23) 
Tighten carefully until snug. 
ST540
Assembly
handle
11/00
ST540
Fig. 23  Assemble the front door handle.
DEFIANT
ST539
attach
thermostat
handle
11/00
ST539
Fig. 22  Attach the thermostat handle.
Fan Kit Installation
1.  Attach the fan assembly at the bottom edge of the inner 
back with two (2) 1/4-20 x 3/4” hex head screws.
2.  Attach snapstat to the mounting holes on the underside 
of the bottom with two (2) 1/4-20 pan head screws.
3.  Attach the rheostat holder (provided with the stove) 
under the right front wing of the bottom heat shield with 
two (2) #10 sheet metal screws.
4.  Attach the rheostat to its holder by inserting the rheo-
stat control shaft through the holder hole. Install the 
retaining ring and rheostat knob onto the shaft.
5.  Secure the rheostat cable to the underside of the bot-
tom heat shield using the wire tie provided and the hole 
at the right rear edge of the heat shield.
6.  Fan will not operate until stove reaches approximately 
43° C (109° F).
Fig. 24  Fan installation (Kit # 2767).
�����
�����������
����
Rheostat 
Knob
Rheostat
Snapstat
Screws
ST848
Hole for Wire  
Tie to Secure 
Cable
Rheostat 
Holder