TROUBLESHOOTING
Continued
OBSERVED  PROBLEM
Burner(s)does  not  light  after
ODS/pilot   is  lit.
Delayed   ignition  of  burner(s).
Burner  backfiring  during  combustion.
Yellow  flame  during  burner
combustion.
Slight   smoke   or   odor   during
initial   operation.
Heater   produces   a  whistling   noise
when  burner  is  lit.
Heater   produces   a  clicking/ticking
noise  just  after  burner  is  lit  or
shut  off.
White  powder residue forming  within
burner    box    or    on    adjacent
walls  or   furniture.
POSSIBLE CAUSE
1.    Burner orifice is clogged.
2.    Burner  orifice  diameter  is too small.
3.    Inlet  gas  pressure  is  too  low.
1.   Manifold  pressure  is  too  low.
2.   Burner orifice is clogged.
1.  Burner   orifice   is  clogged   or
      damaged.
2.   Burner  is damaged.
3.   Gas  regulator  is defective.
1.   Not  enough  air.
2.   Gas  regulator  is defective.
3.   Inlet  gas  pressure  is  too  low .
1.   Residues  from  manufacturing
       processes
.
1.   Turning  control  knob  to  HI position
      when  burner  is  cold.
2.   Air  in  gas  line.
3.  Air   passageways   on   heater
      blocked.
4.   Dirty  or  partially  clogged  burner
      orifice.
1.   Metal  is  expanding  while  heating
      or contracting  while  cooling.
1.   When   heated   the   vapors     from
        furniture    polish,    wax,    carpet
      cleaners,     etc.   turn   into   white
       powder  residue.
REMEDY
1.   Clean burner  orifice (see Cleaning
     and   Maintenance   Page  13)   or
      replace burner orifice.
2.   Replace burner orifice.
3.   Contact  local  natural gas company.
1.   Contact   local  natural gas company.
2.  Clean  burner (see Cleaning  and
      Maintenance
   Page 13)  or replace
      burner  orifice.
1.   Clean  burner  orifice  (see  Cleaning
     and     Maintenance  Page 13)  or
      replace.
2.   Contact Dealer or PRO-COM.
3.   Replace  gas  regulator.
1.  Check  burner  for  dirt  and  debris.
      If  found, clean  burner(see  Cleaning
      And  Maintenance  Page 13).
2.   Replace  gas  regulator.
3.   Contact  local  natural  gas  company.
1.   Problem  will stop after a few hours
      of operation.
1.   Turn  control  knob  to  LO  position
      and  let  warm  up  for  a  minute.
2.   Operate  burner  until air  is removed
      from  line.  Have  gas  line  checked
      by  local  natural  gas  company.
3.   Observe       minimum     installation
      clearances (see Figure 4, Page 7).
4.  Clean burner (see Cleaning  and
      Maintenance
    Page 13)  or  replace
      burner  orifice.
1.  This      is      common    with    most
      heaters.   if   noise    is    excessive,
      contact  qualified  service  person.
1.  Turn   heater   off   when   using
          furniture      polish,      wax,  carpet
       cleaner  or  similar  products.