SPECIFICATIONS
Btu(available)
Gas Type
Ignition
Pressure Regulator setting
Inlet Gas Pressure* (inches of water)
Maximum
Minimum
Dimensions, Inches (HxWxD)
Heater
Carton
Weight (pounds)
Heater
Shipping
MN100HBA
6,000/10,000
Natural  Only
Piezo
3
"
W.C
10.5
"
4
"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
13
16
Note:  Dimensions  listed  are  outer  most  points  on  the  heater  (includes  control  knobs  and  grill).
* For purposes of input adjustment.
EQUIPMENT  SHUTOFF  VALVE
For  all  models. Equipment  shutoff
valve  with  1/8
 NPT  tap.
TECHNICAL SERVICE
You   may   have  further  questions
about    installation,    operation,    or
troubleshooting.    If    so,    contact
PRO-COM through the phone num-
ber 1-877-886-5989.The  information
is listed on the front of  manual.
SERVICE  HINTS
When  Gas  Pressure  Is  Too
Low
l
Pilot  will  not  stay  lit
l
 Burner  will  have  delayed  ignition
l
Heater  will  not  produce specified
    heat
When  Gas  Quality  Is  Bad
Pilot  will  not  stay  lit
Burner  will  produce  flames  and
       soot
Heater  will   backfire   when   lit
You  may  feel  your  gas  pressure  is
too  low  or  the gas  quality  is  poor. If
so, contact  your  local  natural  gas
supplier.
REPLACEMENT  PARTS
Note:  Use  only  original  replacement
parts. This  will  protect  your  warranty
coverage   for   parts   replaced   under
warranty.
PARTS UNDER WARRANTY
Contact   authorized     dealer   from
whom  you  purchased  this  product.
If  they  are  unable  to  supply  original
replacement  part(s),  call  the  num-
ber on the front of this manual.  When
contacting  your  dealer or  PRO-COM,
have ready:
your  name
your  address
model     and    serial    numbers   of
       your  heater
how  heater  was  malfunctioning
type of  gas   used  (propane/LP or
       natural  gas)
purchase  date
warranty card
Usually,  we  will ask you to return the
defective  part  to  the  factory.
PARTS NOT UNDER
WARRANTY
Contact  authorized  dealers  of  this
product.  If  they  can’t  supply  original
replacement part(s),  contact  PRP-
COM  through the phone number 1-
877-886-5989.
MN100TBA
10,000
Natural  Only
Piezo
3
"
W.C
10.5
"
4
"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
14
17
FLOOR  MOUNTING  STAND
Models    MN060HBA,MN100HBA,
MN100TBA
For  locating  heater  on  the  floor  away
from  a  wall.  Complete installation
instructions    provided    with    floor
mounting  stand.
ACCESSORIES
Purchase   these   heater  accesso-
ries from   your   local  dealer.   If   they
can not supply these  accessories,
contact  PRO-COM  for information.
You   can   also   write   to   the  address
listed on the front of  this manual.
MN060HBA
6,000
Natural   Only
Piezo
3
"
W.C
10.5
"
4
"
19-1/8
×
14-1/8
×
6-3/8
22
×
16-3/4
×
8-1/8
12
15