Gas-Fired Products 175 사용자 설명서

다운로드
페이지 53
Form #43343530 
 
 
July 08 
–41– 
 
 
20.0) 
BURNER COMPONENT LOCATIONS 
 
 
 
 
 
 
 
Legend
:
1
Cabinet Assembly
 
2
Access Panel - Top
3
Access Panel - Hinged (2 ea)
4
Access Panel - LH Burner
5
Access Panel - RH Burner
6
Air Inlet Screen
7
Gas Inlet Connection - 1/2”NPT
8
Power Supply Cord - 120V
9
Burner Sight Glass
10
Indicator Light - Amber (Gas Valve)
11
Indicator Light - Red (Air Switch)
12
Tube Flange Connection
13
Main Burner
14
Flame Screen (200m/BTU units only)
15
Electrode
16
Flame Sensor
17
Main Burner Orifice
18
Air Restrictor Plate
2
9
4
3
6
7
8
10
11
5
12
25
Note: This panel
must remain closed
for burner operation.
Note: This panel
must remain closed
for burner operation.
30
3
32
24
1
26
27
28
29
35
14 15
16 13
17
18
19
22
23
20
33
21
34
31
19
Gas Control Valve
20
Ignition Module
21
Ignition Cable
22
Blower Assembly
23
Transformer - 120/24 VAC
24
Terminal Block/Fishpaper Shield
25
Air Switch
26
Air Sensing Tube (P1+)
27
Air Sensing Tube (P2-)
28
Manifold Pipe
29
Manifold Support Bracket/Clamp
30
Terminal Block (24V thermostat)
31
Terminal Block (TISS connection)
32
Starting Collar
33
Valve Holder Plate
34
Fuseholder/Fuse (2 amp)
35
Combustion Air Plate