22.0) TROUBLESHOOTING 
GUIDE 
 
 
 
 
 
Turn on the gas valve?
No
Ye
s
Is 
the 
knob 
on 
the 
gas
valve turned to the ON position?
No
Ye
s
Are the blue wires secure in the terminals and firmly on the ignition module terminals?
Move orange wire to NO terminal. Rest
art
troubleshooting.
Replace motor
.
Remove any obstructions. Repeat st
art up. If motor will
not run. replace motor
.
No
Ye
s
Disconnect 
the 
power
and 
check 
the 
blower
wheel. Does it turn freely?
No
Ye
s
During st
art up, is
there 120V between ground and the IND terminal on the module?
Clean out hoses and probes.
Switch hoses on the pressure t
ap
s.
Check 
NO 
terminal 
of
the air switch connection. Replace red light.
No
Ye
s
Turn on line volt
age
and 
adjust 
thermost
at
to 
the 
highest 
setting.
Does the red monitoring 
light 
come
on?
No
Ye
s
Does the blower come on?
No
Ye
s
Does the LED on the ignition module flash once?
No
Ye
s
Is 
the 
black 
tap 
on 
the
air switch connected to the upper probe?
Check 
the 
probes 
and
hoses 
to 
the 
air 
switch
are they clear and unobstructed?
Replace air switch.
No
Ye
s
Is 
120V 
at 
the 
terminal
block in the blower?
Check line volt
age
circuit. Rep
air fault.
No
Ye
s
Is there 120V between ground and the 
L1 
terminal 
on 
the
module?
No
Ye
s
Check terminals for continuity and rep
air
.
No
Ye
s
Is the LED on the ignition module steady ON?
No
Ye
s
Is 
there 
24V 
between
the inlet to the fuse carrier and the ground?
No
Ye
s
Is there 24V on the other side of the fuse carrier?
No
Ye
s
Is 
there 
24V 
between
both terminals of the TISS and ground?
No
Ye
s
The 
TISS 
has 
broken
continuity
. Check the
first 
tube 
and 
reflector
is there a hole?
Check 
TISS wire for
break 
if 
it 
is 
close 
to
the terminal rep
air
.
Otherwise replace TISS wire.
Replace heat exchanger tube, reflector and 
TISS.
No
Ye
s
Is 
there 
24V 
between
both terminals of the thermost
at 
connection
and ground?
No
Ye
s
Does 
the 
system 
have
a 24V individual thermost
at?
No
Ye
s
Is 
120V 
at 
the 
terminal
block in the blower?
Check 
that 
red 
wire 
is
connected 
to 
TH 
from
air switch terminal C. Rep
air connection.
Replace ignition modules.
Rep
air or replace
jumper check all wire terminals.
Rep
air or replace
thermost
at. Check
external wiring.
Replace ignition module.
Check terminals for continuity at transformer
. If they
are good, replace transformer
.
if fuse carrier is tight and the fuse has no continuity
, replace 
the
fuse.
No
Ye
s
Does the blower st
ay
on?
No
Ye
s
Does the LED on the ignition module flash once?
No
Ye
s
Is the orange wire from 
PSW 
connected
to 
the 
NO 
terminal 
of
the air switch?
No
Ye
s
Are air switch terminals jumpered?
Remove jumper
, air
switch must be open circuit first for blower to operate.
Air switch is stuck in the closed position. Replace air switch.
Move black light wire to NO terminal of the air 
switch. 
Rest
art 
the
troubleshooting.
No
Ye
s
Does the low fire amber 
light 
come 
on?
No
Ye
s
Is the LED on the ignition module steady ON?
No
Ye
s
Af
ter 15 seconds
post purge is there 24V 
between 
V1 
and
V2 ignition module terminals?
Replace ignition module.
Replace ignition module.
Rep
air connection.
Rest
art
troubleshooting.
No
Ye
s
Are the black wires to the amber light securely on the gas valve terminals?
Rep
air connection.
Rest
art
troubleshooting.
Replace amber light. Rest
art
troubleshooting.
Troubleshooting continued 
on 
the 
next
page.