FOR MASONRY BUILT FIREPLACES
FREE  OPENING  AREA  OF  CHIMNEY  DAMPER  FOR 
VENTING COMBUSTION PRODUCTS FROM DECORA-
TIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL 
BURNING FIREPLACES
*   Height is from hearth to top of chimney and the minimum 
height is 6 feet.
**  Chart shows minimum opening (sq. in.) for given height and 
input rate.
•  Turn off gas supply to fireplace or firebox.
•  Have the fireplace floor and chimney professionally cleaned to 
remove ashes, soot, creosote or other obstructions.
  Have this cleaning performed annually after installation.
•  Seal any fresh air vents or ash clean-out doors located on floor 
or wall of fireplace. If not, drafting may cause pilot outage or 
sooting. Use a heat-resistant sealant. Do not seal chimney flue 
damper.
Install and operate the appliance as directed in this manual.
FOR FACTORY BUILT FIREPLACES 
FREE  OPENING  AREA  OF  CHIMNEY  DAMPER  FOR 
VENTING COMBUSTION PRODUCTS FROM DECORA-
TIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL 
BURNING FIREPLACES
*  Height is from hearth to top of chimney and the minimum 
height is 10 feet.
** Chart shows minimum opening (sq. in.) for given height and 
input rate.
Do not attach combustible material to the mantel of your fireplace. 
This is a fire hazard.
Figure 7
No greeting card, stockings or ornamentation of any type should be 
placed on or attached to the fireplace. This is a heating appliance. 
The flow of heat can ignite combustibles.
Figure 8  
Appliance Input Rate (BTU/hr)
20
30
40
Chimney 
Height* (ft)
Minimum Opening** (sq. in.)
10
11.3
16.6
22.1
15
8.6
12.6
17.3
20
7.5
10.8
14.5
25
6.6
9.6
12.6
30
6.2
9.1
11.3
35
5.7
8.0
10.8
40
5.3
7.5
10.2
Appliance Input Rate (BTU/hr)
20
30
40
Chimney 
Height* (ft)
Minimum Opening** (sq. in.)
6
17.6
25.7
33.8
8
16.5
23.7
31.2
10
15.1
21.7
28.7
15
14.1
19.9
26.1
20
12.9
18.5
23.7
30
12.2
16.9
21.6