Vermont Castings Jefferson Direct Vent/Natural Vent Gas Heater
20002191
Venting Requirements - Natural Vent Only
Venting Runs 
Horizontal Run (in feet)
Ve
rtical Run (in f
eet)
(Measured from floor of unit to
top of v
ent cap
.)
A: Vertical installations up to 36 feet (12m) in 
     height. Up to an 18 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 90-degree elbows or four 
     45-degree elbows.
B: Vertical installations up to 36 feet (12m) in 
     height. Up to a 24 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 45-degree elbows. 
     (Ratio = 2/3, Hor./Vert.)
= Acceptable venting configuration
= Unacceptable venting configuration
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
 16  18  20  22  24  26  28  30  32  34  36 
4    6    8    10  12 14
A
B
Fig. 11  Vent termination window - Natural Vent ONLY.
FP567b
NOTE: When using the FSDHAG, the restrictor plate
supplied with the stove is not used.
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
A =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
B =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
A
Balcony - 
with no side wall
G = 
Combustible&
Noncombustible
  12"(305mm)
  
  
G
Balcony - 
with perpendicular side wall
H = 24"(610mm)
J = 20"(508mm)
      
H
J
B
Recessed Location
C = Maximum depth of 48"
       (1219mm) for recessed 
       location.
       
D = Minimum width for back wall 
       of a recessed location.
       Combustible 38"(965mm)
       Noncombustible 24"(610mm)
E = Clearance from corner in 
       recessed location.
       Combustible 6"(152mm)
       Noncombustible 2"(50mm)
C
D
C
E
V
V
Combustible &
Noncombustible
V
V
V
584-14
Fig. 10  Termination clearances.