Dutchwest Natural Vent Gas Heater
30002008
Passing Through a 
Combustible Wall or Ceiling
An approved pass-through device is always required 
when a vent passes through a combustible wall or ceil-
ing. Check with the maker of the vent system for the 
correct listed devices that are available. A listed pass-
through device is required whether or not the installa-
tion includes decorative pipe around the Type B venting 
system.  NOTE: It is essential to seal between the ceil-
ing support (sometimes called a ‘firestop spacer’) and 
the decorative pipe, if installed, with a high-temperature 
silicone sealant. (Fig. 6)
Complete the venting system installation according to 
the manufacturer’s instructions. 
Fig. 7  Vent termination window.
Venting Requirements
FP567
NVBR/NVBC VENTING RUNS
11/12/97
Venting Runs 
A: Vertical installations up to 36 feet (12m) in 
     height. Up to an 18 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 90-degree elbows or four 
     45-degree elbows.
B: Vertical installations up to 36 feet (12m) in 
     height. Up to a 24 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 45-degree elbows. 
     (Ratio = 2/3, Hor./Vert.)
= Acceptable venting configuration
= Unacceptable venting configuration
NOTE: When venting staight vertical, without an
elbow, a minimum of 8 ft. vertical is required
off the top of the stove.
Horizontal Run (in feet)
Vertical Run (in feet)
(Measured from top of the unit before any elbow
)
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
1   2   4     6    8    10  12 14  16  18   20  22  24
A
B
FP567b
ST361
Ceiling pass thru
5/11/00   djt
Joists
Ceiling 
Support
Trim Col-
lar
Air Space
Listed 4” 
(102mm) 
B-Vent
Decorative 
6” Pipe
High-Tempera-
ture Silicone 
Sealant
Air Space as Re-
quired by Code
ST361
Fig. 6  A ceiling pass-through, with decorative pipe around the 
vent.
High-Tem-
perature 
Silicone 
Sealant