Gianni Industries DG-100 사용자 설명서

다운로드
페이지 3
 
Copyright © Gianni Industries, Inc. All Rights Reserved.   
P-MU-DG100-4C  Ver. B  Published on 2007.09.20                                                             Page: 1/ 3
 
 
DG-100 Split Digital Keypad Entry system 
Operation User's Manual (4 Codes)
 
 
 
 
1.  Product Characteristic: 
‹
 
Allows up to 99 PIN codes 
‹
 
Random user codes for anti-peeping 
‹
 
Fully Programmable via keypad and master code 
‹
 
LED display with audible indication 
‹
 Non-Volatile 
Memory 
 
‹
 
Invalid PIN Lock-out  
‹
 
Metal die casting housing 
‹
 
Deftly dimension for narrow jamb 
‹
 
With vandal resistant screws 
‹
 
Split of controller and reader for high security. 
 
 
2. Specifications: 
‹
 
Operating Voltage: 12 Vdc 
‹
 
Current Draw: Average 15mA, Peak 70mA @ 12Vdc  
‹
 
Output: N.O./N.C./Com. Output (free voltage contact)       
‹
 
Relays Rated: 2A MAX @30Vdc ;0.4A @ 120Vac  
‹
 
Relay Activation Time: (*100) 
„
 
Strike Time: 1~99 seconds(adjustable) 
„
 
Strike mode: Access Timer or Latch 
‹
 
PIN codes: 4 digit codes 
‹
 
User codes capacity: 99 slots                             
‹
 
Operating Temperature: -20~+70℃ 
‹
 
Ambient Humidity: 5~95% relative humidity non-condensing 
‹
 
Factory Master Code: 1234 
‹
 
Invalid PIN Lock-out: The system will shut down for 60 seconds while 30 codes of 
incorrectly Master Codes enrolled or PIN codes attempted(None beeper signal of 
keypad activations). 
‹
 
EPROM:  Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 
‹
 Color: 
Beige 
White 
‹
 
Distance between the keypad and controller board: Maximum 50 M (cable#22~26 AWG). 
 
 
3.  The indicator signal chart: 
Sound and LED indicator:  
Green LED
  
Relay activated 
Red LED
 
Power on, stand-by 
LED signal 
Yellow LED 
Programming mode 
1 Beep 
Key-in, Effective PIN codes 
2 Beeps 
Entering 、Exiting from the Program mode 
3 Beeps 
Data computing error 、 other operation mistakes 
Sound signal 
5 Beeps 
Master Code reset to Factory ( 1234 ) or remove all 
stored user codes