Thermo Products OD6FX072DV5R 사용자 설명서

다운로드
페이지 76
 
 48 
 
V. DEALER MAINTENANCE: 
 
SAFETY DURING SERVICING AND INSPECTION 
 
: Personal injury or property damage could result from repair or service of this 
appliance by anyone other than a qualified heating contractor. The user may only perform the 
activities described in the Homeowner/User Routine Maintenance section of this manual.
 
 
: To avoid injury from moving parts, or electrical shock, shut off the power to the 
appliance before removing blower compartment door and servicing this appliance. 
 
: When servicing controls, label all wires prior to disconnecting. Reconnect any 
removed wires correctly. Wiring errors can cause improper and dangerous operation. 
Dangerous operation can result in injury or damage.
 
 
IMPORTANT:  Verify the proper operation of this appliance after any servicing is performed. 
 
A qualified heating contractor should perform the following maintenance procedures at the 
beginning of each heating season. Correct any deficiencies at once.
 
 
A. GENERAL INSPECTION: 
 
c
WARNING:  Shut off oil and disconnect power before continuing with this 
inspection. 
 
1.  Vent terminal - Visually inspect the terminal for restrictions, loose or missing fasteners, external 
damage, and carbon build-up. Clean the vent terminal and the screen(s) covering any opening in 
the terminal. Repair any minor damage. If necessary, replace a severely damaged or degraded 
vent terminal. 
 
2.  Burner – Visually check the burner, and below the burner, for indications of oil leaks. Correct any, 
if found. Remove the burner and measure the ignition electrode gap. It should be set to 5/32 inch. 
Adjust it, if necessary. Clean any accumulation of dust, dirt, or debris from the air shutter or air 
band openings. If necessary, clean housing and blower wheel with a damp cloth. Use a vacuum 
to remove any lint or dust from motor assembly. Add a few drops of non-detergent oil to each of 
the motor lubrication holes. 
  
3.  Combustion Chamber - Inspect the liner for deterioration, oil and carbon build-up. If the 
accumulation of oil or carbon is significant, this is a strong indicator that the burner is out of 
adjustment. Inspect the burner nozzle for partial blockage and excessive wear. Replace it, if 
required. Check and adjust oil pump pressure, if needed. Refer to Initial Heating System 
Adjustments
 section of this manual. 
 
Note: OD6R*072D*** furnaces care must be given to ensure no damage occurs to the chamber 
insert.  (Refer to Figure 12) 
 
4.  Heat Exchanger – Visually inspect the heat exchanger for excessive carbon (soot) build-up. Refer 
to the Heat Exchanger section of the manual. 
 
5.  Oil Filter – Replace the supply line oil filter cartridge with a new filter of the same type and rating. 
Clean the body of, or mounting plate for, the oil filter. 
 
6.  Labels and Markings - Clean all appliance labels, markings, and instruction plates, as necessary, 
and verify that all are still legible. Any illegible or missing markings must be replaced. 
Replacements can be obtained by contacting Thermo Products.