WinterWarm Small Insert
2000888
Operation
Your WinterWarm Insert’s 
Controls and What They Do
All WinterWarm Small Insert controls are conveniently 
located on the front. (Fig. 8)
Three controls regulate the performance of your Winter-
Warm Small Insert:
The primary air control supplies oxygen for the fire.
The damper directs air flow within the fireplace.
The variable-speed fan control, or rheostat, regulates 
the warm air flow into the room.  
FP1099
WWsi
controls
4/01
Damper Control 
Lever
Primary Air 
Control Lever
Fan Speed Control
FP1099
Fig. 8  WinterWarm Small Insert controls.
Primary Air Control
A single air control regulates the amount of heat the fire 
will produce and how long it will burn.
The primary air control lever is located midway up 
the left side panel.  The lever regulates air for starting, 
maintaining, and reviving the fire. 
Generally, more air entering the stove makes the fire 
burn hotter and faster, while less air prolongs the burn.
The WinterWarm Small Insert’s air supply is increased 
when the control lever is moved counterclockwise, and 
decreased when moved clockwise.  It may be set any-
where between the two extremes, however, depending 
on the amount of heat desired. (Fig. 9)
To complement the manual setting of the air control, 
the WinterWarm Small Insert has an internal automatic 
thermostat that ensures an even delivery of heat at the 
manual setting you select.
2:00 High
3:00 Medium
4:00
4:30 Low
FP1100
WWsi
air control settings
4/03/01  djt
Primary Air Control Lever
FP1100
Fig. 9  Settings for the primary air control range from 2:00 
(high burn rate) to 4:30 (low burn rate).
The Damper
The damper directs air flow within the fireplace. The 
damper is operated by moving the lever located above 
the door. It has two positions:  Open, to start or revive 
the fire; and closed, for normal operation. The damper 
is open when the lever is to the far right, and closed 
when to the far left. There are no intermediate settings 
for damper position. (Fig. 12)
To open the damper, insert the fall-away handle into the 
hole in the lever, lift up on the lever and move it to the 
far right.   
To close the damper, move the lever to the left, continu-
ing past the resistance to lock the damper in position.    
FP1072a
WWsi
damper closed
4/3/01
FP1071a
WW si
damper open
4/03/01   djt
Damper 
Secondary Air 
Inlet
Damper
Catalytic 
Combustor
Secondary Air 
Inlet
FP1071/2a
Damper Open
Damper Closed
Fig. 10  When the damper is open, smoke is vented directly 
to the chimney. When the damper is closed, smoke is chan-
nelled through the catalytic combustor.