Castile Pellet Insert
6
Mobile Home
1. 
An outside air inlet must be provided for the combustion 
air and must remain clear of leaves, debris, ice and/or 
snow.  It must be unrestricted while the appliance is 
in  use  to  prevent  room  air  starvation  which  causes 
smoke spillage.  Smoke spillage can also set off smoke 
alarms.  
2. 
The  combustion  air  duct  system  must  be  made  of 
metal.  It must permit zero clearance to combustible 
construction and prevent material from dropping into 
the  inlet  or  into  the  area  beneath  the  dwelling  and 
contain a rodent screen.
3. 
The  appliance  must  be  secured  to  the  mobile  home 
structure by bolting it to the fl oor (using lag bolts). Use 
the same holes that secured the appliance to the ship-
ping pallet.
4. 
The appliance must be grounded with #8 solid copper 
grounding wire or equivalent, terminated at each end 
with an NEC approved grounding device.
5. 
Refer to clearances to combustibles and fl oor protection 
requirements on pages 9 & 10 for listings to combus-
tibles and appropriate chimney systems.
6. 
Use  silicone  to  create  an  effective  vapor  barrier  at 
the  location  where  the  chimney  or  other  component 
penetrates to the the exterior of the structure.
7. 
Follow the chimney manufacturer’s instructions when 
installing the vent system for use in a mobile home.
8. 
Installation shall be in accordance with the Manufactur-
ers Home & Safety Standard (HUD) CFR 3280, Part 
24.
Installation must comply with Manufactured Home and 
Safety Standard (HUD), CFR 3280, Part 24.
WARNING
You must use a Quadra-Fire Outside Air Kit for instal-
lation in a mobile home.
A. Mobile Home Installation
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Approved Class “L” 
or “PL” Pellet Vent
Figure 17.1
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME 
FLOOR, WALL AND CEILING/ROOF MUST BE MAIN-
TAINED
Do NOT cut through:
•  Floor joist, wall, studs or ceiling trusses.
•  Any supporting material that would affect the structural 
integrity.
NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.
WARNING
Asphyxiation Risk.