Quadra-Fire CASTINS-CSB 사용자 설명서

다운로드
페이지 52
Page  18
250-7251G
August 20, 2009
R
Castile Pellet Insert
7
Appliance Set-Up
B.  Leveling System
Figure 18.4
A.  Reversible Top or Rear Flue Adapter
The back legs are adjustable to allow for customized fi t 
into zero clearance boxes.
1.  Loosen 2 top screws and remove 2 bottom screws.
2.  Adjust leg to desired height. Leg can slide up (shorter) 
or down (longer) to level the insert.
3.  Tighten 2 top screws.
4.  Drill 2 holes for the bottom 2 screws and re-install 
screws.  Figure 18.5.
Loosen top 2 screws and remove
bottom 2.  Adjust leg to desired height.
Drill 2 holes and
re-install bottom 2
screws
Ammo Can Latches
Top Vent Installation
1.  Release ammo can latches on each side.  Figure 18.1.
2.  Place the reversible adapter in the correct position for your 
installation.
3.  Make sure BOTH latches are in position before securing 
them.
Rear Vent Installation
1.  Remove the 90
o
 adapter and installation screws from the 
packaging. 
2.  Attach  the  90
o
  adapter  onto  the  vent  adapter,  using  the  3 
screws provided. You will need to pre-drill the holes for screw 
placement.  Be sure to adjust the 90
o
 adapter to the desired 
position for venting before drilling. 
3.  Silicone the pipe joints according to the Note below.
screw
Figure 18.5
Figure 18.1 - Top Vent
Figure 18.2 - Rear Vent
Figure 18.3 - Rear Vent
NOTE:  All pipe must be sealed using welded 
seam pipe whenever possible.  Seal pipe joints 
with high temperature silicone, minimum rate of 
500
0
F (260
0
C).