Castile Pellet Insert
2
Getting Started
A.  Design, Installation & Location Considerations
Warning! Risk of Fire
 
Damaged parts could impair safe 
operation. Do NOT install damaged, incomplete or substitute 
components. 
1. Appliance Location
NOTICE: Check building codes prior to installation.
•  Installation MUST comply with local, regional, state and 
national codes and regulations.
•  Consult  insurance  carrier,  local  building  inspector,  fi re 
offi cials or authorities having jurisdiction over restrictions, 
installation inspection and permits.
It  is  a  good  idea  to  plan  your  installation  on  paper,  using 
exact  measurements  for  clearances  and  fl oor  protection, 
before actually beginning the installation
Consideration must be given to:
•  Safety, convenience, traffi c fl ow
•  Placement of the chimney and chimney connector.  
•  If you are not using an existing chimney, place the appli-
ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.  
•  Installing an optional outside air kit would affect the loca-
tion of the vent termination.
CAUTION!
   
If  burning  shelled  fi eld  corn,  you  must  use  ap-
proved venting specifi cally designed for corn to prevent corro-
sion or degradation.  Follow the instructions from the venting 
manufacturer.
Since pellet exhaust can contain ash, soot or sparks, you 
must consider the location of:
•  Windows
•  Air Intakes
•  Air Conditioner
•  Overhang, soffi ts, porch roofs, adjacent walls 
•  Landscaping, vegetation
When  locating  vent  and  venting  termination,  vent  above 
roof line when possible.
Marginal Location:
•  Below peak
Location NOT recommended:
•  Not the highest point of the roof
•  Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
•  Above peak
Recommended:
•  Insulated exterior chase 
in cooler climates
Recommended Location:
•  Above peak
•  Inside heated space
Location NOT recommended:
•  Too close to tree
•  Below adjacent structure
•  Lower roof line
•  Avoid outside wall
Marginal Location:
•  Wind loading possible
NOTICE:    Locating  the  appliance  in  a  location  of 
considerable air movement can cause intermittent smoke 
spillage from appliance. Do not locate appliance near:
• 
Frequently open doors
• 
Central heat outlets or returns
Figure 5.1