Figure 11: Restrictor plate settings.
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 12. Possible Vent Configurations for Top Vented; 
Vertical and Horizontal Terminations.
The ENVIRO WESTPORT has been designed with a 
built in restrictor plate. The restrictor is designed to 
enhance  flame  appearance  when  installing  this  unit 
with  vertical  chimneys  as  well  as  installations  with 
longer  horizontal  vent  applications.  It  does  this  by 
controlling the amount of air moving through the vent 
pipe.
Figure 12 shows the vent restrictor position required, 
relative  to  the  length  of  vent  pipe.    Longer  vertical 
vent lengths necessitate greater restriction; position 
1 is open and position 5 is maximum restriction (refer 
to Figure 11). To avoid injury, it is best to make this 
adjustment when the fireplace is cool or use welder’s 
gloves or oven mitts.
NOTE:  The  total  length  of  the  vent  pipes  can  not  exceed 
30 feet (9.14 m). Any combination of rise and run can be 
used as long as it lays within the shaded area (a total 
of three (3) 90° elbows or six (6) 45° elbows can 
be used). In addition to what is shown, if a 90° 
elbow is used in the horizontal plane, 3 feet 
(91.4  cm)  must  be  subtracted  from  the 
allowable horizontal run (for each 45° 
elbow, 11⁄2 feet must be subtracted 
from  the  allowable  horizontal 
run). 
To access vent restrictor remove the valve 
cover  plate  from  the  right  rear  corner  of 
the  unit  by  undoing  the  two  fastening 
screws.
Loosen the 1⁄4” hex head bolt and adjust to 
the correct setting.
Slide the hex head bolt to the next setting 
and re-tighten the bolt to secure in place.
The  numbers  in  this  chart  represent  the 
actual  vent  restrictor  settings.  Although 
the numbers do not appear on the unit use 
this as a guide to follow.
Undo the setscrew and adjust the restrictor 
to the correct setting.
Ensure that the setscrew is re tightened and 
the unit is checked for proper operation. 
Wait  for  unit  to  warm  up  to  operating 
temperature  to  ensure  proper  and  clean 
burning unit.
Note:  0,0  in  Figure  12  represents  a  90˚ 
bend directly off the outlet of the unit, in 
all horizontal instances except when using 
Selkirk and having less than a 4 ft (1.22 m) 
rise and 8 ft (2.44 m) horizontal offset. In 
this case, a 1 foot (30.5 cm) rise must be 
added below the 90˚ bend.
14