Initial Installation
QUALIFIED INSTALLERS ONLY
H
ORIZONTAL
 I
NSTALLATION
:
STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are 
in the way when the venting system is attached. If this is the case, you may want to adjust the 
location of the appliance.
STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the 
desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented 
towards the wall or floor, as much out of view as possible.
 
Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a 
bead of high temperature silicone on the male edge of the outer pipe. Push the pipe sections 
completely together, then twist-lock one section clockwise approximately 1⁄4 turn, until the two 
sections are fully locked. The female locking lugs will not be visible from the outside, on black 
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 16: Twist-Lock Connection
Woodscrews
Wall Thimble
Strap
Sheet metal
screws
Fold strap
here
1
1
/
4
"
(3.2cm)
Figure 18: Installing Decorative Wall Thimble.
10"
(254mm)
10"
(254mm)
Figure 17: Wall Framing Hole for 
Horizontal Installation. 
16
pipe. They may be located by examining the inside of the 
female ends as shown in Figure 16.
Notes: 
(1)  Twist-lock  procedure: 
four 
(4) 
indentations, 
located  on  the  female  end 
of the pipes and fittings, are 
designed  to  slide  straight 
onto  the  male  ends  of 
adjacent  pipes  and  fittings, 
by  orienting  the  four  pipe 
indentations  so  they  match 
and slide into the four entry 
slots on the male end.
(2)  Horizontal  runs  of  vent 
pipe  must  be  supported