Gas-Fired Products PTU 사용자 설명서
MODEL
PTS/U 40
40,000
40,000
25,000
PTS/U 50
50,000
50,000
30,000
PTS/U 75
75,000
75,000
50,000
PTS/U 100
100,000
100,000
65,000
MODEL SELECTIONS
GENERAL FEATURES
•
•
8 different Btu/hr sizes and more than 100
different configurations to custom design your
infrared heating system
different configurations to custom design your
infrared heating system
•
Single Stage or Two Stage Input Controls
•
CSA design certified
•
Vented or indirect vented operation
•
Sidewall or through-the-roof venting
•
Natural and propane gas models
PUSH THROUGH SYSTEM
(Positive Pressure)
•
Products of combustion are pushed through the
combustion chamber
combustion chamber
•
Tube Integrity Safety System (TISS)
•
No draft hoods, totally enclosed
combustion chamber
combustion chamber
•
Blower motor totally enclosed in the burner box.
Ideal for applications where minimal noise (less
than 60dB) is desired
Ideal for applications where minimal noise (less
than 60dB) is desired
•
Heavy duty permanently lubricated, ball bearing
blower motor for maintenance-free operation
blower motor for maintenance-free operation
BURNER SYSTEM
•
•
Heavy-duty cast iron burner
•
10-year limited warranty on burner
•
Inside or outside air for combustion
•
Up to 40 ft. outside combustion air duct capability
•
Standard 4” combustion air collar
•
Reliable direct spark ignition system and 100%
gas shut-off safety control
gas shut-off safety control
•
Pre-purge and post-purge function
•
State-of-the-art step opening redundant
combination gas valve for quiet ignition and
added safety
combination gas valve for quiet ignition and
added safety
•
Diaphragm air switch for proof of venting before
gas flow and ignition
gas flow and ignition
•
Diagnostic monitoring light system
•
Burner inspection sight glass
•
Line voltage or 24V thermostat connection
RADIANT EMITTER TUBE SYSTEM
•
•
4” O.D. heavy-duty calorized aluminized steel or
alumi-therm steel combustion chamber (10 feet)
and heavy duty hot-rolled steel radiant emitter
tubes
alumi-therm steel combustion chamber (10 feet)
and heavy duty hot-rolled steel radiant emitter
tubes
•
Optional calorized aluminized steel (ALC)
radiant emitter tubes
radiant emitter tubes
•
3-year limited warranty on the emitter tubes
•
Suitable for horizontal or angle mounting up to 45°
•
Optional 90° elbows
•
Up to 40 feet sidewall vent capacity
REFLECTOR SYSTEM
•
•
Highly efficient aluminum reflectors with
reflectivity rating of 97.5%
reflectivity rating of 97.5%
•
Optional end, corner, side and U-bend reflectors
•
Optional decorative grille
•
Individual reflectors can be rotated up to 45° to
direct heat where needed
direct heat where needed
•
Easy-to-use mounting brackets and wire hangers
TOTAL EMITTER TUBE LENGTH*
10 FT**
20 FT
30 FT
40 FT
PTS/PTU SERIES FEATURES
GAS
TYPE
NATURAL
3.5” W.C.
5” W.C*
14” W.C.
PROPANE
10” W.C.
11” W.C.*
14” W.C.
BURNER
PRESSURE
VOLTAGE
AMPS
IGNITION
TYPE
MIN
MAX
120 VAC
60 HZ
1.8
DIRECT
SPARK
*Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 40 feet) and gas type
(e.g., natural gas single stage input). The unit selection for a straight tube would be PTS100-40-N5 and for a U-tube
would be PTU100-40-N5. **Available only on PTS models.
(e.g., natural gas single stage input). The unit selection for a straight tube would be PTS100-40-N5 and for a U-tube
would be PTU100-40-N5. **Available only on PTS models.
ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes
for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses,
Swimming Pools, Waste Water Treatment Plants, and other high humidity / corrosive environments, the ALC option with
all calorized aluminized tubes is recommended.
for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses,
Swimming Pools, Waste Water Treatment Plants, and other high humidity / corrosive environments, the ALC option with
all calorized aluminized tubes is recommended.
SUPPLY PRESSURE
SINGLE
STAGE
BTU/HR
INPUT
FLUE
CONNECTION
OUTSIDE COMBUSTION
AIR CONNECTION
4” Round
4” Round
Btu/hr
High Input
Btu/hr
Low Input
TWO STAGE
X
X
X
X
X
X
X
X
MODEL
PTS/U 125
125,000
125,000
80,000
PTS/U 150
150,000
150,000
100,000
PTS/U 175
175,000
175,000
110,000
PTS/U 200
200,000
200,000
125,000
TOTAL EMITTER TUBE LENGTH*
30 FT
40 FT
50 FT
60 FT
70 FT
SINGLE
STAGE
BTU/HR
INPUT
Btu/hr
High Input
Btu/hr
Low Input
TWO STAGE
X
X
X
X
X
X
X
X
X
X
X
X
CONTROL SUFFIX
N5 / L5
N7 / L7
TYPE OF GAS
Natural / Propane
Natural / Propane
CONTROL OPTION DESCRIPTION
Single Stage Gas Valve - Single Stage Input
Two Stage Gas Valve - Two Stage Input - High/Low Fire
®
Energy efficient PTS150-40 installed in a manufactur-
ing application.