Operator’s Manual
Installation
INSTALLATION
IMPORTANT:  Review  and  understand  the  warnings  in 
the Safety Information section. They are needed to safely 
operate this space heater. Follow all local ordinances and 
codes when using this space heater.
 
WARNING:  TEST  ALL  GAS  PIPING  AND  
 
 
CONNECTIONS  FOR  LEAKS  AFTER  
 
 
INSTALLING  OR  SERVICING.  NEVER  
 
 
USE AN OPEN FLAME TO CHECK FOR  
 
 
A LEAK. APPLY A MIXTURE OF LIQUID  
 
 
SOAP AND  WATER  TO ALL  JOINTS.  
 
 
BUBBLES  FORMING  SHOW A  LEAK.   
 
 
CORRECT ALL LEAKS AT ONCE.
1. Provide propane supply system (see Propane 
Supply).
2. Connect fuel gas connector fitting on hose / regulator 
assembly to Propane / L.P. tank(s). Turn counterclockwise 
into threads on tank valve. Tighten firmly using wrench.
  IMPORTANT: Tighten regulator with vent pointing down.  
Pointing  vent  down  protects  regulator  from  weather 
damage.  (Fig. 1)
3. Connect hose to inlet connector. Tighten firmly using a 
wrench. (Fig. 2)
  IMPORTANT: Extra hose or piping may be used if needed.  
Install  extra  hose  or  piping  between  hose/regulator 
assembly  and  Propane  /  L.P.  tank. You  must  use  the 
regulator supplied with heater.
4. Open propane supply valve on Propane / L.P. tank(s) 
slowly. 
Note: If not opened slowly, excess-flow check valve on 
Propane / L.P. tank will stop gas flow. If this happens, 
close propane supply valve and open again slowly.
5. Check all connections for leaks. 
6. Close propane supply valve.
Hose
Regulator
Vent (pointing
down)
Supply
Valve
Propane
Tank
Fuel Gas
Connector
(Fig. 1)
Hose
Inlet Connector
(Fig. 2)
Operation
OPERATION
 
WARNING:  FOLLOW  THE  MINIMUM  FRESH,  
 
 
O U T S I D E   A I R   V E N T I L AT I O N   
 
 
REQUIREMENTS. IF PROPER FRESH,  
 
 
OUTSIDE  AIR  VENTILATION  IS  NOT  
 
 
PROVIDED,  CARBON  MONOXIDE  
 
 
POISONING  CAN  OCCUR.  PROVIDE  
 
 
PROPER  FRESH,  OUTSIDE  AIR  
 
 
VENTILATION  BEFORE  RUNNING  
 
 
HEATER.
START SPACE HEATER:
1. Follow all ventilation and safety information.
2. Place  the  space  heater  in  an  area  that  provides 
maximum circulation of the heated air. Follow all location 
requirements noted in the Safety Information.