Friedrich YM18 사용자 설명서

다운로드
페이지 56
6
920-198-00
Allow 3 min. between restarts
S P E E D
Sleep
Setting
Low
Cool
Medium
Cool
High
Cool
Fan
Only
Off
MIN
MAX
Money Saver
®
Yes
No
Allow 3 min. between restarts
Money Saver
®
MAX
COOL
MAX
HEAT
Low
Cool
Med
Cool
High
Cool
Low
Heat
Med
Heat
High
Heat
Fan
Only
Off
Yes
No
To start unit
If your air conditioner is installed and plugged into a properly grounded 
re cep ta cle, it is ready to op er ate.
Mode control (QuietMaster ‘K’ and Heavy Duty)
The upper dial (Figure 5) allows you to select cooling at four different 
speeds, as well as Fan Only (Models SL28 and SL36 only have three 
cooling speeds.). 
Off - to turn the unit off.
High Cool - for quick cooling. 
Medium Cool - to maintain a de sired temperature. 
Low Cool - when cooling demand is low. 
Sleep Setting - for nighttime use, or when cooling demand is low.
Fan Only - to circulate air in the room without the compressor coming on. 
The Fan Only setting can also be used with the Exhaust air set ting to remove 
stale air or smoke from the room; or it can be used with the Fresh Air setting 
to bring outside air into the room. This is especially useful in the spring and fall 
when cooling may not be nec es sary. The Fresh Air and Exhaust controls 
are in the upper air discharge area. The center po si tion of this control is the 
normal, or closed position, which recirculates air for maximum performance 
in the cool ing mode (See Figure 9).
Mode control (Twintemp)
This dial allows you to select cooling or heat ing at three different speeds, 
as well as Fan Only (Figure 6).
Off - to turn the unit off.
High Cool or High Heat - for quick re sponse.
Medium Cool or Medium Heat - to main tain a de sired temperature.
Low Cool or Low Heat - for nighttime use, or when demand is low.
Fan Only - to circulate air in the room without the compressor coming on. 
The Fan Only set ting can also be used with the Exhaust air set ting to 
re move stale air or smoke from the room, or it can be used with the Fresh 
Air setting to bring outside air into the room, es pe cial ly in the spring and 
fall when cool ing isn’t nec es sary.
The Fresh Air and Exhaust con trols are in the up per air discharge area 
(see Figure 9, page 7). The cen ter position of this control is the normal, or 
closed po si tion, which re cir cu lates air for max i mum per for mance in the 
cool ing  mode.
NOTE: You may notice an odor when fi rst ac ti vat ing the heat when the 
electric heat el e ment comes on. This is due to dust burning off that may 
have gath ered on the coil during the sum mer. This is normal.
Temperature control
The bottom dial on the control panel is the thermostat. Turn it clock wise 
for cooler temperature and counterclockwise for warmer.
Money Saver
®
 switch
This rocker switch can be depressed to either Yes or No. In the Yes position 
you will get the most eco nom i cal operation. Both the fan and com pres sor 
will cy cle on and off to geth er, main tain ing the se lect ed tem per a ture at a 
more con stant lev el and re duc ing the hu mid i ty more ef fi  cient ly in the cooling 
mode. This control will only op er ate when the unit is in cooling or heating 
mode. In the No position, the fan will run con stant ly as long as the unit is 
in the cooling or heat ing mode.
NOTE: The YS09 is a 115 volt model and does not provide adequate heat 
below 37°F (3°C). This prod uct is designed for warm climate ap pli ca tions.
How to operate your Friedrich room air con di tion er 
(QuietMaster 'K' & Heavy Duty models / Twintemp models)
Figure 5
Figure 6