Toshiba RAV-SM1402CT-E 사용자 설명서

다운로드
페이지 195
– 32 –
RAV-SM803UT-E, RAV-SM802BT-E, RAV-SM802CT-E / RAV-SM803AT-E
Standard
Cooling
Overload
Low load
Standard
Heating
Overload
Low load
Pressure
(MPa)
(kg/cm²G)
Pd
Ps
Pd
Ps
3.28
0.86
33.4
  8.8
3.59
1.00
33.6
10.2
1.85
0.83
18.9
  8.5
2.53
0.62
25.8
  6.3
3.42
1.07
34.9
10.9
1.99
0.23
20.3
  2.3
Pipe surface temperature (°C)
Discharge
(TD)
84
82
42
75
80
89
Suction
(TS)
 11
  17
   8
   3
 20
–19
Indoor heat
exchanger
(TC)
10
16
  6
42
54
34
Outdoor heat
exchanger
(TE)
 45
 51
 23
   2
 17
–18
Compressor
revolutions per
second (rps)
*
  83
  76
  35
  95
  50
120
Indoor
fan
HIGH
HIGH
LOW
HIGH
LOW
HIGH
Indoor/Outdoor
temp. conditions
(DB/WB) (°C)
Indoor
Outdoor
27/19
35/–
32/24
43/–
18/15.5
–5/–
20/–
7/6
28/–
24/18
15/–
–10/(70%)
*
4 poles are provided to this compressor.
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Indoor unit
Outdoor unit
TCJ 
sensor
Air heat exchanger
Strainer
TC sensor
TD 
sensor
TS 
sensor
TO sensor
TE
sensor
Distributor
4-way valve
(STF-0213Z)
2-step 
muffler
Ø25 × 200L
Rotary 
compressor
(DA150A1F-20F)
Accumulator
(1000cc)
Heat exchanger
Ø8 ripple, 2 rows, 
20 steps
FP1.3 flat fin
PMV
(Pulse Motor Valve)
(CAM-B30YGTF-1)
R410A 1.6 kg
Cooling
Heating
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
15.9mm
9.5mm
Height difference (m)
Outdoor unit
at upper side
Outdoor unit
at lower side
30
30
Refrigerant pipe 
at gas side 
Ø15.9
Refrigerant pipe 
at liquid side 
Ø9.5
Packed valve
Outer dia. ØA
Packed valve 
Outer dia. ØB
Max.
30m
Min.
5m
Muffler
Ø19 × L160
4 pass
Height diff
erence
Section shape
of heat insulator
Revised : Mar. 2007