4 poles are provided to this compressor.
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Indoor unit
Outdoor unit
Distributor
(Strainer incorporated)
(Strainer incorporated)
TCJ sensor
Air heat exchanger
Strainer
Strainer
TC sensor
Strainer
Ball valve
Outer dia. ØA
Packed valve
Outer dia. ØB
Max.
50m
50m
Min.
5m
5m
TS sensor
TD sensor
TO sensor
TE
sensor
sensor
Distributor
4-way valve
(STF-0213Z)
Ø25 × L210
Ø25 × L180
Rotary
compressor
(DA420A3F – 21M)
Accumulator
(2500cc)
Heat exchanger
Outer side
Ø8, 2 rows, 20 steps
FP1.3 flat fin
Inner side
Ø9.52 row, 30 steps
FP1.5 flat fin
Outer side
Ø8, 2 rows, 20 steps
FP1.3 flat fin
Inner side
Ø9.52 row, 30 steps
FP1.5 flat fin
R410A 2.8kg
Cooling
Heating
Heating
Muffler
Refrigerant pipe
at gas side Ø15.9
at gas side Ø15.9
Refrigerant pipe
at liquid side Ø9.5
at liquid side Ø9.5
PMV
(Pulse Motor Valve)
(UKV-25D22)
(Pulse Motor Valve)
(UKV-25D22)
Height diff
erence
Section shape
of heat insulator
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
15.9mm
9.5mm
Height difference (m)
Outdoor unit
at upper side
Outdoor unit
at lower side
at lower side
30
30
Standard
Cooling
Overload
Low load
Standard
Heating
Overload
Low load
Pressure
(MPa)
(kg/cm²G)
Pd
Ps
Pd
Ps
3.44
0.92
35.1
9.4
3.73
1.18
38.1
12.0
1.49
0.70
15.2
7.1
2.80
0.61
28.6
6.2
3.43
1.08
35.0
11.0
2.20
0.25
22.4
2.6
Pipe surface temperature (°C)
Discharge
(TD)
82
82
39
80
82
76
Suction
(TS)
8
15
8
0
14
–19
Indoor heat
exchanger
(TC)
10
17
3
46
55
36
Outdoor heat
exchanger
(TE)
39
48
22
1
13
–16
Compressor
revolutions per
second (rps)
*
47
42
30
48
24
55
Indoor
fan
HIGH
HIGH
LOW
HIGH
LOW
HIGH
Indoor/Outdoor
temp. conditions
(DB/WB) (°C)
Indoor
Outdoor
27/19
35/–
32/24
43/–
18/15.5
–5/–
20/–
7/6
30/–
24/18
15/–
–10/(70%)