For safe, effi cient operation, the vent damper and all 
fl ue product carrying areas of the appliance must be 
checked annually by you, with particular attention 
given to deterioration from corrosion or other 
sources.  If you see corrosion or other deterioration, 
contact your heating contractor for repairs.  Check 
vent damper operation as follows:
When the boiler is off, check that the vent damper 
1. 
positions indicator points to the closed position, Fig. 
8.
Turn the thermostat or controller up to call for heat 
2. 
and check the vent damper indicator points to the open 
position, Fig. 8.
Turn the thermostat or controller down again and check 
3. 
that the damper position indicator returns to the closed 
position.
If you have central air conditioning, set the thermostat 
4. 
to COOL and turn it down to call for cooling.  Cooling 
system should operate.
Return thermostat to desired position.
5. 
The vent damper must be inspected at least 
once a year by a trained, experienced service 
technician.  The name of the person who 
originally installed your vent damper is shown 
on the installation label.
MANUAL OPERATION OF THE VENT DAMPER
The vent damper may be placed in the open position 
to permit burner operation by using the “HOLD 
DAMPER OPEN” switch, located on the damper 
controller.  The thermostat will control the burner 
fi ring as before, while the damper will remain open.  
VENT DAMPER OPERATION
DO NOT turn damper open manually or motor 
damage will result.  Set switch to “AUTOMATIC 
OPERATION” to close vent damper during burner off 
cycle.
For further information, and for a vent damper 
troubleshooting guide, refer to the manual that was 
packaged with the vent damper.
Figure 8 - Vent Damper Position Indicator
GAS SUPPLY PIPING
!
CAUTION
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• 
Do not touch any electrical switch; do not use 
• 
any phone in your building.
Immediately call your gas supplier from a 
• 
neighbor’s phone.  Follow gas supplier’s 
instructions. 
If you cannot reach your gas supplier, call the 
• 
fi re department.
General
Use piping materials and joining methods acceptable 
• 
to authority having jurisdiction.  In absence of such 
requirements:
USA - National Fuel Gas Code, ANSI Z223.1/NFPA 
• 
54
Canada - Natural Gas and Propane Installation Code, 
• 
CAN/CSA B149.1
Install fi eld sourced manual main shutoff valve and 
• 
ground joint union.
Size and install gas piping system to provide 
• 
suffi cient gas supply to meet maximum input at not 
less than minimum supply pressure. See Table 4a & 
4b.
NOTICE
Use two (2) wrenches when installing pipe to 
gas valve. Boiler's gas valve can be damaged 
if subjected to excessive torque.
Support piping with hooks straps, bands, brackets, 
• 
hangers, or building structure components to prevent 
or dampen excessive vibrations and prevent strain on 
gas connection.  
Use thread (joint) compound (pipe dope) suitable for 
• 
liquefi ed petroleum gas.