Regency Wraps F33 사용자 설명서

다운로드
페이지 28
20
Regency
®
 F33-3 Freestanding Gas Stove
Note: 
Before troubleshooting the gas control system, be sure external gas shut off is in the "on" position.
TROUBLESHOOTING THE GAS CONTROL SYSTEM
WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT.
 POSSIBLE
     PROBLEM 
 CAUSES 
               CORRECTIVE ACTION
TROUBLESHOOTING GUIDE
Spark igniter will not 
light pilot.
Pilot will not stay lit 
after carefully fol-
lowing lighting in-
structions.
Pilot burning, no gas 
to burner.
Valve knob is on. 
Wall switch is on.
Frequent pilot out-
age problems.
 
Piezo wire loose
Defective Piezo igniter.
Piezo wire grounding out.
Electrode is grounding out 
and/or wrong location.
Defective thermopile.
Defective thermocouple.
Thermopile/thermocouple 
grounding out.
Loose thermopile leads.
TP-THTP on valve.
Defective automatic gas 
valve.
Valve wire connections are 
loose.
Valve wires are defective.
Spill switch has not been 
reset (B-vent F/S).
Spill switch is stuck in the 
open position. (B-vent INS 
- F/S).
Pilot fl ame may be too low 
or blowing high causing the 
pilot safety to drop out.
Two way switch wires may 
be grounding out.
Thermopile and/or thermo-
couple may be grounding 
out.
•   Check for spark at electrode and pilot. If no spark, disconnect wire 
at electrode and put wire to ground and try igniter again. If still no 
spark follow Piezo wire to Piezo igniter to see where grounding may 
be occurring.
•  Bend electrode into pilot so gas may be able to contact spark.
•  Check pilot fl ame, must impinge on thermopile and thermocouple.
•  Clean and/or adjust pilot so pilot is enveloped around thermopile 
and thermocouple.
•  Be sure wire connections at gas valve terminals are tight and ther-
mopile and thermocouple are fully inserted into pilot bracket.
•  One of the switch wires may be grounded. May be grounded to gas 
appliance or gas supply.
•  Check thermopile with millivolt meter. Take reading at thermopile 
terminals of valve TP-TPTH. Should read 250 millivolts minimum 
while holding valve knob in pilot position with pilot on and wall 
switch/two way switch off.
•  Replace if lower than specifi ed minimum.
•  Turn valve knob to on including pilot. Take reading at TP-TPTH with 
on/off switch in the on position. Reading should be 100mv or greater. 
If reading is okay and pilot does not hold, replace gas valve.
•  Check two way switch/wall switch for proper connections. Jumper 
wire across terminals at two way switch/wall switch. If burner comes 
on, replace switch.
•  If okay, jumper wire at valve at TH-THTP.  If unit turns on, replace 
wires and/or check where loose wires are.
•  Clean and/or adjust pilot for maximum fl ame impingement on 
thermopile and/or thermocouple.
•  Trace wires from valve to two way switch/wall switch for possible 
grounding against gas appliance and/or gas supply.
•  Trace thermopile wires from valve to thermopile for possible 
grounding against gas appliance and/or gas valve.
•  Follow same steps for thermocouple.
Note: 
For service technicians only. See the Regency
®
 Troubleshooting Guide for more detailed information. 
 (Troubleshooting 
Regency
®
 Gas Products)
MAINTENANCE
                                                                                          
ABNORMAL OPERATION
If the main burner does not light but pilot stays on shut down heater and contact your dealer
If excessive carbon on logs or glass contact your dealer