Optional Installation Instructions
S o m e   c o m p a c t   m o d e l s   h a v e   o p t i o n a l   p l u m b i n g 
connections.  On  these  units,  if  top  connection  is 
preferred over the side connection, use the  following 
instructions as they apply to your connection:
To  change  Temperature  and  Pressure  (T&P)  valve 
location:  Remove  3/4”  plug  from  opening  in  jacket 
top.  Replace  3/4”  plug  opening  with  T&P  valve; 
plug  original  T&P  valve  opening  with  3/4”  plug. 
BE 
SURE  TO  REAPPLY  PIPE  jOINT  COMPOUND  OR 
TEFLON  TAPE  AROUND  THE  THREADED  ENDS 
OF  THE  TEMPERATURE  AND  PRESSURE  (T&P) 
VALVE AND THE 3/4” PLUG WHEN REINSTALLING 
COMPONENTS.
To change Cold Inlet location: Remove 3/4” plug from 
opening in jacket top. Replace 3/4” plug opening with 
Cold Inlet nipple; plug original Cold Inlet opening with 3/4” 
plug. 
BE SURE TO REAPPLY PIPE jOINT COMPOUND 
OR TEFLON TAPE AROUND THE THREADED ENDS 
OF  THE  COLD  INLET  NIPPLE AND  THE  3/4”  PLUG 
WHEN REINSTALLING COMPONENTS.
To change Hot Outlet location: Screw 3/4” NPT galvanized 
cap (not included, purchase locally) onto Side Hot Outlet 
and  install  3/4”  NPT  nipple  (not  included,  purchase 
locally) in the opening identified as HOT/T&P location. 
BE  SURE  TO  REAPPLY  PIPE  jOINT  COMPOUND 
OR TEFLON TAPE AROUND THE THREADED ENDS 
OF  THE  3/4”  NPT  NIPPLES  WHEN  REINSTALLING 
COMPONENTS.
T & P Valve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from 
carton.
Fit  pipe  insulation  over  the  incoming  cold  water  line  and  the 
hot water line. Make sure that the insulation is against the side 
jacket of the heater.
Fit T & P valve insulation over valve. Make sure that the insulation 
does not interfere with the lever of the T & P valve.
Secure all insulation using tape.
FIGURE 9A.
NOTE:  Figure  above  is  used  to  illustrate  installation  of 
T&P  and  pipe  insulation  only. As  indicated  in  PRODUCT 
SPECIFICATION Section. Actual optional Cold & Hot / T&P 
spud location vary from model to model.
Temperature-Pressure Relief Valve
This  heater  is  provided  with  a  properly  certified  combination  
temperature - pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing laboratory 
that maintains periodic inspection of production of listed equipment 
of  materials  as  meeting  the  requirements  for  Relief  for  Hot 
Water Supply Systems, ANSI Z21.22 • CSA 4.4, and the code 
requirements of ASME.
If replaced, the valve must meet the requirements of local codes, 
but not less than a combination temperature and pressure relief 
valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to 
exceed the marked hydrostatic working pressure of the water 
heater (150 psi = 1,035 kPa) and a discharge capacity not less 
than the water heater input rate as shown on the model rating 
plate. (Electric heaters - watts x 3.412 equal Btu/hr input rate)
Your  local  jurisdictional  authority,  while  mandating  the  use 
of  a  temperature-pressure  relief  valve  complying  with 
ANSI Z21.22 • CSA 4.4, may require a valve model different 
from the one furnished with the water heater.
Compliance  with  such  local  requirements  must  be  satisfied 
by the installer or end user of the water heater with a locally