Smelly  water  may  be  eliminated  or  reduced  in  some  water 
heater models by replacing the anode rod(s) with one of less 
active material, and the chlorinating the water heater tank and 
all water lines. Contact the local Sears Service Center for further 
information concerning an Anode Replacement Kit #9001453 
and  this  Chlorination  Treatment. 
Anode  replacement  and 
chlorination of the tank are not covered by the water heater’s 
limited warranty.
If smelly water persists, after anode replacement and chlorination 
treatment,  you  should  consider  chlorinating  or  aerating  your 
water supply.
Do not remove the anode leaving the tank unprotected. By 
doing so, all warranty on the water heater tank is voided.
  
“AIR” IN HOT WATER FAUCETS
HYDROGEN  GAS:  Hydrogen  gas  can  be  produced  in  a  hot 
water system that has not been used for a long period of time 
(generally  two  weeks  or  more).  Hydrogen  gas  is  extremely 
flammable  and  explosive. To  prevent  the  possibility  of  injury 
under  these  conditions,  we  recommend  the  hot  water  faucet 
be opened for several minutes at the kitchen sink before any 
electrical  appliances  which  are  connected  to  the  hot  water 
system are used (such as a dishwasher or washing machine). 
If hydrogen gas is present, there will probably be an unusual 
sound similar to air escaping through the pipe as the hot water 
faucet is opened. There must be no smoking or open flame near 
the faucet at the time it is open.
RUMBLING NOISE
In some water areas, scale or mineral deposits will build up on 
your heating elements. This buildup will cause a rumbling noise. 
Follow  “Element  Cleaning/Replacement”  instructions  to  clean 
and replace the elements.
HIGH TEMPERATURE SHUT OFF SYSTEM
The water heater has a high limit shut off system with a reset 
button located on the thermostat.
Follow  the  resetting  instructions  which  refer  to  the  high  limit 
behind the access panel.
1.  Before beginning, turn “OFF” electrical power supply to the 
water heater.
FIGURE 30.
2.  Remove the screw(s) securing the access panel and remove 
panel.
3. Remove the insulation.
4.  Reset  the  high  limit  by  pushing  in  the  red  button  marked 
“RESET”.
                                 
                                         
FIGURE 31.
5.  Replace  the  insulation  so  that  it  completely  covers  the 
thermostat and element.
6.  Replace the access panel.
7.  Turn “ON” electric power to the water heater.
If the high limit must be reset again, call Sears Service Department 
to find out why high limit turned “OFF” the electric power.