NOT ENOUGH OR NO HOT WATER
1.   In a new installation, the water heater may not be properly 
connected. Make sure the cold water supply valve is open. Review 
and check piping installation. Make sure that the cold water line is 
connected to the cold water inlet to the water heater and the hot 
water line to the hot water outlet on the water heater.
2.   Make sure the electrical supply to your water heater is “ON”.
3.   Check for loose or blown fuses in your water heater circuit.
  Circuit breakers weaken with age and may not handle their 
rated load and should be replaced.
4.   Make certain the disconnect switch, if used, is in the “ON” 
position.
5.  Check to see the electric service to your house has not been 
interrupted. If this is the case, contact the electric company.
6.   Is  the  thermostat  set  to  the  desired  temperature?  See 
“Temperature Regulation” section.
7.  If you had experienced very hot water and now no hot water, 
the problem may be due to the high temperature shut off 
system.  See  “High Temperature  Shut  Off  System”  in  the 
“Troubleshooting” section.
8.  During very cold weather, the incoming water will also be 
colder and it will require a longer time to become heated.
9.  The hot water usage may exceed the capacity of the water 
heater. If so, wait for water heater to recover after abnormal 
demand. Also examine pipes and faucets for possible water 
leaks.
10. If you can not determine the problem, then call the Sears 
Service Department.
WATER IS TOO HOT
Adjust the thermostat to a lower setting. See the “Temperature 
Regulation” section.