JAI CV-A1-20 사용자 설명서

다운로드
페이지 24
CV-A1-20
 
5.4. CV-A1 Block Diagram 
 
Fig. 8. Block diagram. 
6. Functions and Operations 
6.1. Basic functions 
Some of the primary camera functions need a general introduction before the operation modes 
are described. The list below shows the primary functions from the command list. 
 
 
SM  Shutter Mode 
Normal shutter, Programmable Exposure 
 
SH  Shutter Speed 
Off to 1/140,000 second 
 
PE  Programmable Exposure  1.3 H to 1023.3 H 
 
SC  Scanning Format 
Full frame, 1/2 partial, 1/3, 1/6 partial 
 
BI  Binning 
Off, vertical, horizontal, vertical + horizontal 
 
TR  Trigger Mode 
Normal, Edge, PWC, frame delay readout 
 
 
 
Long time exposure, start-stop, smearless (Edge) 
 HC 
HD 
Accumulation  Sync., 
async. 
 
The shutter SM can be set to normal (SM=0), where the exposure time is selected from 16 fixed 
step with the command SH, or programmable exposure (SM=1). The command PE allows 1023 
step with 1 line period resolution. (83.6 µs). Note that PE=0 and PE=1 results in 1.3H. 
The CCD scanning format SC can be selected between full or partial scanning. With partial 
scanning, only the vertical central part of the CCD sensor is read out with a higher frame rate. 
The partial scan is done by a fast dump read out of the lines in the vertical ccd register down to 
the top of the partial image. The partial part of the image is read out with normal speed.  The 
lines below the partial image are read out and dumped with a high speed.  
Some signal distortion can be expected below highlighted areas, (saturated areas). It is caused 
by limitation in the vertical ccd register transfer efficiency at high speed. 
  
 
Imaged scene
Partial scanning.
Aspect ratio correct
1380 pixels 
1/2 PS, 51
3 pixels
1/6 PS, 171 pixe
ls
1/3 PS, 341 pix
els
 
 
 
 
 
 
 
 
Fig. 9. Partial scanning. 
 
- 6 -