Binning mode BI is a function where the signal charge from 2 or more adjacent pixels are added 
together and read out as one pixel. A resulting full frame with lower resolution can be read out 
with a higher rate. By adding 2 pixels together, the sensitivity is doubled. The CV-A1-20 has both 
vertical and horizontal binning. With V binning the pixel charge from 2 adjacent lines are added 
together in the horizontal ccd register. It is done by double pulses to the vertical ccd register. 
With H binning the pixel charge from 2 horizontal adjacent pixels are added together in the 
sample/hold circuit after the horizontal ccd register. It is done by shifting the charge from 2 
horizontal ccd cells into the sample/hold capacitor for each reset pulse.  
Both vertical and horizontal binning can work together. The sensitivity is then 4 times normal. 
The aspect ratio will be correct, if the sampling frequency is divided with 2. See fig. 10. 
Xsg1
Video out
pix
Pclk out
:2
Pclk out
No H binning
Horizontal ccd register
S/H
Reset
S/H
Reset
pix
Pclk out
:2
Pclk out
No H binning
Horizontal ccd register
S/H
Reset
S/H
Reset
V and H binning.
Aspect ratio correct
Vertical binning
690 pixels
1380 pixels
50
1 pi
xel
s
5
01 p
ixel
s
V and H binning.
Aspect ratio correct
Vertical binning
690 pixels
1380 pixels
50
1 pi
xel
s
5
01 p
ixel
s
pix
H binning
No V binning
V binning
H
V
er
tic
a
l c
cd
 r
eg
is
te
r
Xsg1
Video out
pix
H binning
No V binning
V binning
H
V
er
tic
a
l c
cd
 r
eg
is
te
r
Normal full scanning.
Aspect ratio correct
Horizontal binning
Displayed image with binning
1380 pixels 
690 pixels
10
35
p
ixel
s
103
5
p
ixel
s
H binning is 2:1. V is 2:1. Together it is a 4 :1 binning
Normal full scanning.
Aspect ratio correct
Horizontal binning
Displayed image with binning
1380 pixels 
690 pixels
10
35
p
ixel
s
103
5
p
ixel
s
H binning is 2:1. V is 2:1. Together it is a 4 :1 binning
 
Fig. 10. Binning. 
 
The accumulation mode HC can be set to asynchronous accumulation (HC=1). The exposure in 
PWC mode (TR =2) and Frame Delay readout (TR=3) will start immediately at the leading edge of 
the trigger pulse without waiting for the HD. Fig. 11 and fig. 12 shows the details. 
 
 
X b
HD
Trigger
X b
Accum
HD
Trigger
Accum
Fig. 11. PWC H synchronous accumulation                  Fig 12. PWC asynchronous accumulation 
 
In normal trigger mode (TR=0) shutter speed up to 1/140,000 sec. can be used. In all triggered 
shutter modes, the shortest shutter time is limited to ≥1,3 H. (1/8381). In triggered shutter 
modes with partial scan or binning, the longest shutter speed is not limited by the frame read 
out time. It can be longer. 
 
Trigger modes with possible scanning and binning combinations 
Scanning 
Full scanning 
Partial scanning 
 
TR= 
Binning  norm.  V 
V+H  Norm 
V+H 
 
Remarks 
Normal 
√ 
√ 
√ 
√ 
√ 
n n n  SM=0, 
SM=1 
active 
Edge Pre-sel. 
√ 
√ 
√ 
√ 
√ 
n n n  SM=0, 
SM=1 
active 
Pulse Width 
√ 
√ 
√ 
√ 
√ 
n n n  HC=0, 
HC=1 
active 
Fr. Delay r.o. 
√ 
√ 
√ 
√ 
√ 
n n n  HC=0, 
HC=1 
active 
Long Time int 
√ 
n n n  n 
     
 
Start/Stop 
√ 
 
 
 
 
 
 
 
 
Smearless 
√ 
√ 
√ 
√ 
√ 
n n n  SM=0, 
SM=1 
active 
√ Described 
mode 
 
n  
Non-described mode combination, which will work 
 