JAI TM/TMC-4200CL 사용자 설명서

다운로드
페이지 70
Page 48
Serial Communication Kit
TM/TMC-4200CL Series Progressive Scan Cameras
7.2 TM-4200CL Command List
The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:” 
and the End character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode, 
send the command :SA9“CR” to the camera. The following table contains RS-232 commands that can 
be used to control the camera.
TABLE 7.
TM-4200CL Command List 
Command
Parameter
End of 
Cmd
Ack. Response
Description
Scan Mode
:SMD
X
<cr>
:o<cr>
Set Preset Scan Area 
(X=A,B,C,D,T)
:SMDZ=
X
<cr>
:o<cr>
Set Digital Zoom (X=0,1,2,3)
:SMDU=
XXXXYYYY
<cr>
:o<cr>
Set Programmable Scan Area 
(XXXX=0000 - 07FF, 
YYYY=0001 - 0800)
:SMD?
<cr>
:oMD[X]<cr>
Inquire current scan mode 
(X=A,B,C,D,T,Z,U)
Shutter Mode and Shutter Speed
:MSH=
X
<cr>
:o<cr>
Set Continuous Mode Preset Shut-
ter ( X= 0 - 9)
:DSH=
XXX
<cr>
:o<cr>
Set Continuous Mode Program-
mable Shutter ( XXX=000 - total 
lines)
:ASH=
X
<cr>
:o<cr>
Set Async Mode Preset Shutter 
(X=0 - 9, A, B) ( X=0 async no 
shutter,
( X=1-8 Preset Shutter, X=9 
PWC,  X=A Fixed exposure PIV, 
X=B PWC PIV)
:ADS=
XXX
<cr>
:o<cr>
Set Async Mode Programmable 
Shutter (XXX=000 - 81F)
:SHR?
<cr>
:o[shtr]<cr>
Inquire current shutter mode
Gain and Offset
:MGA=
XXX
<cr>
:o<cr>
Set Master Gain 
(XXX = 000 - FFF)
:MGB=
XXX
<cr>
:o<cr>
Set R channel Fine Gain 
(XXX = 000 - FFF)
:VRA=
XXX
<cr>
:o<cr>
Set Master Offset 
(XXX = 000 - FFF)