JAI TM/TMC-4200CL 사용자 설명서

다운로드
페이지 70
Page 49
Serial Communication Kit
TM/TMC-4200CL Series Progressive Scan Cameras
Command
Parameter
End of 
Cmd
Ack. Response
Description
Gain and Offset Continued
:VRB=
XXX
<cr>
:o<cr>
Set R channel Fine Offset
(XXX = 000 - FFF)
:MGA?
<cr>
:oMG[XXX]<cr
>
Inquire Master Gain 
(XXX = 000 - FFF)
:MGB?
<cr>
:oSG[XXX]<cr>
Inquire R channel Fine Gain 
(XXX = 000 - FFF)
:VRA?
<cr>
:oMF[XXX]<cr>
Inquire Master Offset 
(XXX = 000 - FFF)
:VRB?
<cr>
:oSF[XXX]<cr>
Inquire R channel Fine Offset
(XXX = 000 - FFF)
Lookup Table
:LINR
<cr>
:o<cr>
Set linear table
:GM45
<cr>
:o<cr>
Set gamma .45 table
:KNEE=
X1Y1X2Y2
<cr>
:o<cr>
Set knees 
(X1, Y1, X2, Y2 = 00 - FF)
:NLUT
X
<cr>
:o<cr>
Set Positive Knee or Negative 
Knee (X = 0 Positive, X = 1 
Negative)
:LUT?
<cr>
:o[lut]<cr>
Inquire current LUT setting
Channel Balance
:EABL
<cr>
:oAB0<cr>
Enable Gain Balancing
:DABL
<cr>
:o<cr>
Disable Gain Balancing
:ABL?
<cr>
:oAB[X]<cr>
Check Gain Balancing Status 
(X = 1 Enable, X = 0 Disable)
:ACL=
X
<cr>
:o[AC][X]<cr>
Enable/Disable Optical Black Bal-
ancing and Inquire Status
(X = 0 Disable, X = 1 Enable, 
X = ? Inquire Status)
Vsub
:DCI=
XXX
<cr>
:o<cr>
Set Vsub (XXX = 600 - D00)
:DCI?
<cr>
:oDC[XXX]<cr>
Inquire Vsub (XXX = 600 - D00)